Percutaneous closure of an iatrogenic ventricular septal defect associated with transcatheter aortic valve implantation.
Savas, Göktug; Yazici, Selçuk; Kiliç, Özgür; Terzi, Sait.
Afiliación
  • Savas G; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
  • Yazici S; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
  • Kiliç Ö; Department of Coronary Care Unit, Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
  • Terzi S; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
Turk Kardiyol Dern Ars ; 50(1): 70-78, 2022 Jan.
Article en En | MEDLINE | ID: mdl-35197236
An 81-year-old man who had dyspnea was admitted to our hospital with a diagnosis of severe aortic stenosis. A transcatheter aortic valve implantation was successfully performed with a 29 mm Edwards Sapien XT valve using a transfemoral access. After the procedure, the echocardiography showed a restrictive ventricular septal defect (VSD) in the membranous septum. As the patient had no symptoms, it was decided to follow him up conservatively. However, he was readmitted within three weeks with symptoms suggestive of biventricular failure. A control echocardiography revealed a membranous VSD, 8 mm in size, right chambers dilatation with moderate tricuspid regurgitation, and systolic pulmonary artery pressure of 60 mm Hg. The previously deployed aortic valve was normal in function. The decision to perform a percutaneous VSD closure was made. The defect was then closed with a 10 mm muscular VSD occluder. During and after the procedure, there was no dysfunction in the bioprosthetic aortic valve. At the one-year follow-up, the patient was still asymptomatic.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reemplazo de la Válvula Aórtica Transcatéter / Defectos del Tabique Interventricular Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Aged80 / Humans / Male Idioma: En Revista: Turk Kardiyol Dern Ars Asunto de la revista: CARDIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Turquía Pais de publicación: Turquía

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reemplazo de la Válvula Aórtica Transcatéter / Defectos del Tabique Interventricular Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Aged80 / Humans / Male Idioma: En Revista: Turk Kardiyol Dern Ars Asunto de la revista: CARDIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Turquía Pais de publicación: Turquía