Your browser doesn't support javascript.
loading
Clinical outcomes of a beveled tip, ultra-high speed, 25-gauge pars plana vitrectomy system.
Uy, Harvey S; Cabahug, Vicente Lorenzo O; Artiaga, Jose Carlo M; Chan, Pik Sha; Famadico, Jordan T.
Afiliación
  • Uy HS; Peregrine Eye and Laser Institute, Morning Star Center, 347 Gil Puyat Avenue, Bel Air, 1209, Makati City, Philippines. harveyuy@yahoo.com.
  • Cabahug VLO; Department of Ophthalmology and Visual Sciences, University of the Philippines, Manila, Philippines. harveyuy@yahoo.com.
  • Artiaga JCM; Eye Institute, St Luke's Medical Center, Quezon City, Philippines. harveyuy@yahoo.com.
  • Chan PS; Cebu Doctors' University Hospital, Cebu City, Philippines.
  • Famadico JT; Moorfields Eye Hospital NHS Foundation Trust, London, UK.
BMC Ophthalmol ; 22(1): 93, 2022 Feb 24.
Article en En | MEDLINE | ID: mdl-35196996
OBJECTIVE: To report the clinical outcomes of a 25-gauge, beveled-tip, 10,000 cuts-per-minute (cpm) microincisional vitrectomy surgery (MIVS) system. METHODS: Prospective case series of eyes undergoing primary pars plana vitrectomy (PPV) for common vitreoretinal indications. Main outcome measures were: rate of achieving surgical objectives, operative times, number of surgical steps, use of ancillary instruments, corrected distance visual acuity (CDVA), and adverse events (AE). RESULTS: The surgical objectives were achieved in all eyes. Mean total operative time (TOT), core, shave and total vitrectomy times were 1891 ± 890, 204 ± 120, 330 ± 320, 534 ± 389 s, respectively. Mean number of surgical steps was 4.3 ± 1.5. Mean number of ancillary instruments used was 4.5 ± 1.9. Mean CDVA improved by 0.53 ± 0.56 logMAR units (P < 0.001) 3 months postoperatively. AE included elevated IOP (8%), hypotony (6%), and re-detachment (2%). Majority (82%) had no postoperative discomfort. The number of surgical steps demonstrated a positive correlation with TOT (p < 0.05), number of ancillary instruments used (p < 0.05), and postoperative Day 1 IOP (p < 0.05). The number of times ancillary instrumentation was used demonstrated a positive correlation with TOT (p < 0.05). CONCLUSION: Beveled-tip, 10,000 cpm MIVS system effectively and safely performs common VR procedures of varying complexity and may reduce operative times and use of ancillary instrumentation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vitrectomía / Glaucoma Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Filipinas Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vitrectomía / Glaucoma Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Filipinas Pais de publicación: Reino Unido