Your browser doesn't support javascript.
loading
Trapped p waves causing loss of physiological left bundle branch pacing.
de Castro, Daniel; Aguilera-Agudo, Cristina; Castro-Urda, Víctor; Toquero, Jorge; Jimenez-Sanchez, Diego; Vela-Martín, Paula; Veloza-Urrea, Darwin; Fernandez-Lozano, Ignacio; García-Izquierdo, Eusebio.
Afiliación
  • de Castro D; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • Aguilera-Agudo C; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • Castro-Urda V; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • Toquero J; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • Jimenez-Sanchez D; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • Vela-Martín P; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • Veloza-Urrea D; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • Fernandez-Lozano I; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
  • García-Izquierdo E; Arrhythmia Unit. Cardiology Department, University Hospital Puerta de Hierro, Madrid, Spain.
Pacing Clin Electrophysiol ; 45(7): 896-899, 2022 07.
Article en En | MEDLINE | ID: mdl-35191070
We present the case of a 75-year-old woman with severe aortic stenosis and moderate left ventricular dysfunction, who underwent elective transcatheter aortic valve replacement. After the procedure, the patient developed a left bundle branch block and a long PR interval. For this reason, a dual chamber pacemaker with pacing in the left bundle branch area was implanted. On device interrogation, we confirmed the presence of functional atrial undersensing causing loss of ventricular electric resynchronization. This case highlights the importance of recognizing this problem and, by means of device reprogramming and pharmacological intervention, suggests a stepwise approach to solve it.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Reemplazo de la Válvula Aórtica Transcatéter Límite: Aged / Female / Humans Idioma: En Revista: Pacing Clin Electrophysiol Año: 2022 Tipo del documento: Article País de afiliación: España Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Reemplazo de la Válvula Aórtica Transcatéter Límite: Aged / Female / Humans Idioma: En Revista: Pacing Clin Electrophysiol Año: 2022 Tipo del documento: Article País de afiliación: España Pais de publicación: Estados Unidos