Your browser doesn't support javascript.
loading
A prospective randomized study of arthroscopic ACL reconstruction with adjustable- versus fixed-loop device for femoral side fixation.
Asif, Naiyer; Khan, Mohammad Jesan; Haris, K P; Waliullah, Shah; Sharma, Anubhav; Firoz, Danish.
Afiliación
  • Asif N; Department of Orthopaedic Surgery, Faculty of Medicine, JNMCH, AMU, Aligarh, Uttar Pradesh, India.
  • Khan MJ; Department of Orthopaedic Surgery, Faculty of Medicine, JNMCH, AMU, Aligarh, Uttar Pradesh, India. mzkhan2k1@gmail.com.
  • Haris KP; Department of Orthopaedic Surgery, Faculty of Medicine, JNMCH, AMU, Aligarh, Uttar Pradesh, India.
  • Waliullah S; Department of Orthopaedics, KGMU, Lucknow, Uttar Pradesh, India.
  • Sharma A; Department of Orthopaedic Surgery, Faculty of Medicine, JNMCH, AMU, Aligarh, Uttar Pradesh, India.
  • Firoz D; Department of Orthopaedic Surgery, Faculty of Medicine, JNMCH, AMU, Aligarh, Uttar Pradesh, India.
Knee Surg Relat Res ; 33(1): 42, 2021 Dec 04.
Article en En | MEDLINE | ID: mdl-34863318
PURPOSE: Suspensory devices are extensively used in the management of anterior cruciate ligament (ACL) tear. They include fixed- and adjustable-loop devices. There are only a few studies comparing the efficacy of these two devices in the available literature. Therefore, the aim of this study is to compare clinical outcomes between the adjustable-loop device (group I) and fixed-loop device (group II). MATERIALS AND METHODS: This was a prospective randomized study. Both groups were equivalent in demographic, preoperative, and intraoperative variables. Twenty-three patients underwent femoral side graft fixation with adjustable-loop and 20 with fixed-loop devices. Four patients were lost to follow-up. Assessment of clinical outcome was done with International Knee Documentation Committee (IKDC) score, Lysholm score, and knee stability tests (Lachman test and pivot shift test). Patient evaluation was performed preoperatively and finally postoperatively 2 years after surgery. RESULTS: Postoperative IKDC scores of group I and II were 91.9 ± 3.6 and 91.5 ± 3.6, respectively, and Lysholm scores were 91.0 ± 3.6 and 91.4 ± 3.5, respectively, after 2 years; however, the difference in the outcomes was statistically insignificant (p > 0.05). Twenty patients (87%) in group I and 17 patients (85%) in group II had a negative Lachman test (p = 0.8). Twenty-two patients (95.7%) in group I and 19 patients (95%) in group II had a negative pivot shift test (p = 0.9). CONCLUSION: ACL reconstruction with fixed- and adjustable-loop suspensory devices for graft fixation gives equivalent and satisfactory clinical results. LEVEL OF EVIDENCE: 1.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: Knee Surg Relat Res Año: 2021 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: Knee Surg Relat Res Año: 2021 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido