A prospective randomized study of arthroscopic ACL reconstruction with adjustable- versus fixed-loop device for femoral side fixation.
Knee Surg Relat Res
; 33(1): 42, 2021 Dec 04.
Article
en En
| MEDLINE
| ID: mdl-34863318
PURPOSE: Suspensory devices are extensively used in the management of anterior cruciate ligament (ACL) tear. They include fixed- and adjustable-loop devices. There are only a few studies comparing the efficacy of these two devices in the available literature. Therefore, the aim of this study is to compare clinical outcomes between the adjustable-loop device (group I) and fixed-loop device (group II). MATERIALS AND METHODS: This was a prospective randomized study. Both groups were equivalent in demographic, preoperative, and intraoperative variables. Twenty-three patients underwent femoral side graft fixation with adjustable-loop and 20 with fixed-loop devices. Four patients were lost to follow-up. Assessment of clinical outcome was done with International Knee Documentation Committee (IKDC) score, Lysholm score, and knee stability tests (Lachman test and pivot shift test). Patient evaluation was performed preoperatively and finally postoperatively 2 years after surgery. RESULTS: Postoperative IKDC scores of group I and II were 91.9 ± 3.6 and 91.5 ± 3.6, respectively, and Lysholm scores were 91.0 ± 3.6 and 91.4 ± 3.5, respectively, after 2 years; however, the difference in the outcomes was statistically insignificant (p > 0.05). Twenty patients (87%) in group I and 17 patients (85%) in group II had a negative Lachman test (p = 0.8). Twenty-two patients (95.7%) in group I and 19 patients (95%) in group II had a negative pivot shift test (p = 0.9). CONCLUSION: ACL reconstruction with fixed- and adjustable-loop suspensory devices for graft fixation gives equivalent and satisfactory clinical results. LEVEL OF EVIDENCE: 1.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Tipo de estudio:
Clinical_trials
Idioma:
En
Revista:
Knee Surg Relat Res
Año:
2021
Tipo del documento:
Article
País de afiliación:
India
Pais de publicación:
Reino Unido