Your browser doesn't support javascript.
loading
The sensitivity and specificity of rotational thromboelastometry (ROTEM) to detect coagulopathy during moderate and severe postpartum haemorrhage: a prospective observational study.
Bell, S F; Roberts, T C D; Freyer Martins Pereira, J; De Lloyd, L; Amir, Z; James, D; Jenkins, P V; Collis, R E; Collins, P W.
Afiliación
  • Bell SF; Department of Anaesthetics, Cardiff and Vale University Health Board, Cardiff, UK. Electronic address: sarah.bell3@wales.nhs.uk.
  • Roberts TCD; Department of Anaesthetics, Cardiff and Vale University Health Board, Cardiff, UK.
  • Freyer Martins Pereira J; Department of Anaesthetics, Cardiff and Vale University Health Board, Cardiff, UK.
  • De Lloyd L; Department of Anaesthetics, Cardiff and Vale University Health Board, Cardiff, UK.
  • Amir Z; Department of Anaesthetics, Cardiff and Vale University Health Board, Cardiff, UK.
  • James D; Department of Maternity, Cardiff and Vale University Health Board, Cardiff, UK.
  • Jenkins PV; Haemostasis and Thrombosis, Cardiff and Vale University Health Board, Cardiff, UK.
  • Collis RE; Department of Anaesthetics, Cardiff and Vale University Health Board, Cardiff, UK.
  • Collins PW; School of Medicine, Cardiff University, Cardiff, UK.
Int J Obstet Anesth ; 49: 103238, 2022 Feb.
Article en En | MEDLINE | ID: mdl-34840018
INTRODUCTION: Point-of-care viscoelastic haemostatic assays such as rotational thromboelastometry (including ROTEM and TEG) have been used in the management of postpartum haemorrhage (PPH). This study compared results obtained from the automated ROTEM Sigma with laboratory tests of coagulation and platelet count during PPH. METHODS: A prospective observational cohort study recruited women with PPH ≥1000 mL (or clinical concern of bleeding). The Fibtem A5, Extem CT and Pltem (Extem A5 - Fibtem A5) results were compared with laboratory tests of fibrinogen, prothrombin time (PT), activated partial thromboplastin time (APTT) and platelet count. RESULTS: 521 women were recruited, including 274/277 (98.9%) of women with PPH ≥1500 mL. Fibtem A5 results were matched with laboratory fibrinogen in 552/644 (85.7%) samples. The incidence of abnormal laboratory results was low: fibrinogen ≤2 g/L 23/464 (5.0%), PT or APTT >1.5 × midpoint of reference range 4/464 (0.9%), and platelet count <75 × 109/L 11/477 (2.3%). Area-under-the-receiver operator characteristic curve for Fibtem A5 to detect fibrinogen ≤2 g/L was 0.96 (95% Confidence Interval (CI) 0.94 to 0.98, P<0.001), with sensitivity and specificity of Fibtem A5 ≤11 mm to detect fibrinogen ≤2 g/L of 0.76 and 0.96. Prolonged Extem CT results improved after treatment of hypofibrinogenaemia alone. Intervention points for platelet and fresh frozen plasma (FFP) transfusion based on ROTEM Sigma parameters could not be established. CONCLUSION: During PPH (≥1000 mL or cases of clinical concern about bleeding), ROTEM Sigma Fibtem A5 can detect fibrinogen ≤2 g/L and guide targeted fibrinogen replacement. Laboratory results should continue to be used to guide platelet and FFP transfusion.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trastornos de la Coagulación Sanguínea / Hemorragia Posparto Tipo de estudio: Diagnostic_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Int J Obstet Anesth Asunto de la revista: ANESTESIOLOGIA / OBSTETRICIA Año: 2022 Tipo del documento: Article Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trastornos de la Coagulación Sanguínea / Hemorragia Posparto Tipo de estudio: Diagnostic_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Int J Obstet Anesth Asunto de la revista: ANESTESIOLOGIA / OBSTETRICIA Año: 2022 Tipo del documento: Article Pais de publicación: Países Bajos