Trends in Polyethylene Design and Manufacturing Characteristics for Total Knee Arthroplasty: An Analysis From the American Joint Replacement Registry.
J Arthroplasty
; 37(4): 659-667, 2022 04.
Article
en En
| MEDLINE
| ID: mdl-34826567
BACKGROUND: Advances in polyethylene bearing characteristics have led to various options for total knee arthroplasty. We examine trends in use of polyethylene in the United States. METHODS: An analysis of American Joint Replacement Registry data from 2012 to 2019 for primary total knee arthroplasty procedures was conducted. Design and manufacturing characteristics were obtained and validated in the American Joint Replacement Registry dataset. Polyethylene bearing design and manufacturing use characteristics were compared by year, gender, age group, and geographic region of the procedure. Descriptive analysis was performed. RESULTS: We identified 993,292 cases over the study period. In total, 791,233 (80%) cases had complete device data available and were included in analysis. In addition, 366,280 (49.4%) cases utilized minimally stabilized bearings compared to 374,809 (50.6%) for posterior-stabilized bearings. Posterior-stabilized use was stable over the study period and highest in the Northeast (64.5%; P < .0001). Cruciate-retaining use decreased from 29.7% to 20.2% and anterior-stabilized use increased from 17.4% to 25.2%. Conventional polyethylene use decreased from 42.8% to 21.9%, and was highest in the 81+ age group (37.8%; P < .0001) and Northeast (43.0%; P < .0001). Highly cross-linked polyethylene (HXLPE) with antioxidant use increased from 9.08% to 31.8%, while HXLPE without antioxidant use remained constant. CONCLUSION: There was an increase in use of anterior-stabilized and pivot bearings and an increase in use of HXLPE with antioxidant. Additionally, there were noted age group and regional differences in the use of various bearings. Further study should evaluate if these changing utilization trends are related to clinical outcomes, or due to regional training, preferences, or manufacturer pressures. LEVEL OF EVIDENCE: Level III, retrospective.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Artroplastia de Reemplazo de Rodilla
/
Prótesis de la Rodilla
Tipo de estudio:
Observational_studies
/
Prognostic_studies
Límite:
Humans
País/Región como asunto:
America do norte
Idioma:
En
Revista:
J Arthroplasty
Asunto de la revista:
ORTOPEDIA
Año:
2022
Tipo del documento:
Article
Pais de publicación:
Estados Unidos