Carbon Dioxide Changes during High-flow Nasal Oxygenation in Apneic Patients: A Single-center Randomized Controlled Noninferiority Trial.
Anesthesiology
; 136(1): 82-92, 2022 01 01.
Article
en En
| MEDLINE
| ID: mdl-34758057
BACKGROUND: Anesthesia studies using high-flow, humidified, heated oxygen delivered via nasal cannulas at flow rates of more than 50 l · min-1 postulated a ventilatory effect because carbon dioxide increased at lower levels as reported earlier. This study investigated the increase of arterial partial pressure of carbon dioxide between different flow rates of 100% oxygen in elective anesthetized and paralyzed surgical adults before intubation. METHODS: After preoxygenation and standardized anesthesia induction with nondepolarizing neuromuscular blockade, all patients received 100% oxygen (via high-flow nasal oxygenation system or circuit of the anesthesia machine), and continuous jaw thrust/laryngoscopy was applied throughout the 15-min period. In this single-center noninferiority trial, 25 patients each, were randomized to five groups: (1) minimal flow: 0.25 l · min-1, endotracheal tube; (2) low flow: 2 l · min-1, continuous jaw thrust; (3) medium flow: 10 l · min-1, continuous jaw thrust; (4) high flow: 70 l · min-1, continuous jaw thrust; and (5) control: 70 l · min-1, continuous laryngoscopy. Immediately after anesthesia induction, the 15-min apnea period started with oxygen delivered according to the randomized flow rate. Serial arterial blood gas analyses were drawn every 2 min. The study was terminated if either oxygen saturation measured by pulse oximetry was less than 92%, transcutaneous carbon dioxide was greater than 100 mmHg, pH was less than 7.1, potassium level was greater than 6 mmol · l-1, or apnea time was 15 min. The primary outcome was the linear rate of mean increase of arterial carbon dioxide during the 15-min apnea period computed from linear regressions. RESULTS: In total, 125 patients completed the study. Noninferiority with a predefined noninferiority margin of 0.3 mmHg · min-1 could be declared for all treatments with the following mean and 95% CI for the mean differences in the linear rate of arterial partial pressure of carbon dioxide with associated P values regarding noninferiority: high flow versus control, -0.0 mmHg · min-1 (-0.3, 0.3 mmHg · min-1, P = 0.030); medium flow versus control, -0.1 mmHg · min-1 (-0.4, 0.2 mmHg · min-1, P = 0.002); low flow versus control, -0.1 mmHg · min-1 (-0.4, 0.2 mmHg · min-1, P = 0.003); and minimal flow versus control, -0.1 mmHg · min-1 (-0.4, 0.2 mmHg · min-1, P = 0.004). CONCLUSIONS: Widely differing flow rates of humidified 100% oxygen during apnea resulted in comparable increases of arterial partial pressure of carbon dioxide, which does not support an additional ventilatory effect of high-flow nasal oxygenation.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Terapia por Inhalación de Oxígeno
/
Apnea
/
Administración Intranasal
/
Dióxido de Carbono
Tipo de estudio:
Clinical_trials
Límite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Anesthesiology
Año:
2022
Tipo del documento:
Article
País de afiliación:
Suiza
Pais de publicación:
Estados Unidos