A deep learning approach for synthetic MRI based on two routine sequences and training with synthetic data.
Moya-Sáez, Elisa; Peña-Nogales, Óscar; Luis-García, Rodrigo de; Alberola-López, Carlos.
Afiliación
  • Moya-Sáez E; Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain. Electronic address: http://www.lpi.tel.uva.es.
  • Peña-Nogales Ó; Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain.
  • Luis-García R; Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain.
  • Alberola-López C; Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain.
Comput Methods Programs Biomed ; 210: 106371, 2021 Oct.
Article en En | MEDLINE | ID: mdl-34525411
BACKGROUND AND OBJECTIVE: Synthetic magnetic resonance imaging (MRI) is a low cost procedure that serves as a bridge between qualitative and quantitative MRI. However, the proposed methods require very specific sequences or private protocols which have scarcely found integration in clinical scanners. We propose a learning-based approach to compute T1, T2, and PD parametric maps from only a pair of T1- and T2-weighted images customarily acquired in the clinical routine. METHODS: Our approach is based on a convolutional neural network (CNN) trained with synthetic data; specifically, a synthetic dataset with 120 volumes was constructed from the anatomical brain model of the BrainWeb tool and served as the training set. The CNN learns an end-to-end mapping function to transform the input T1- and T2-weighted images to their underlying T1, T2, and PD parametric maps. Then, conventional weighted images unseen by the network are analytically synthesized from the parametric maps. The network can be fine tuned with a small database of actual weighted images and maps for better performance. RESULTS: This approach is able to accurately compute parametric maps from synthetic brain data achieving normalized squared error values predominantly below 1%. It also yields realistic parametric maps from actual MR brain acquisitions with T1, T2, and PD values in the range of the literature and with correlation values above 0.95 compared to the T1 and T2 maps obtained from relaxometry sequences. Further, the synthesized weighted images are visually realistic; the mean square error values are always below 9% and the structural similarity index is usually above 0.90. Network fine tuning with actual maps improves performance, while training exclusively with a small database of actual maps shows a performance degradation. CONCLUSIONS: These results show that our approach is able to provide realistic parametric maps and weighted images out of a CNN that (a) is trained with a synthetic dataset and (b) needs only two inputs, which are in turn obtained from a common full-brain acquisition that takes less than 8 min of scan time. Although a fine tuning with actual maps improves performance, synthetic data is crucial to reach acceptable performance levels. Hence, we show the utility of our approach for both quantitative MRI in clinical viable times and for the synthesis of additional weighted images to those actually acquired.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aprendizaje Profundo Tipo de estudio: Guideline / Qualitative_research Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2021 Tipo del documento: Article Pais de publicación: Irlanda

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aprendizaje Profundo Tipo de estudio: Guideline / Qualitative_research Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2021 Tipo del documento: Article Pais de publicación: Irlanda