[Technology specification of bedside hypertonic saline-contrast electrical impedance tomography of lung perfusion and clinical application].
He, H W; Long, Y; Chi, Y; Yuan, S Y; Zhou, X; Su, L X; Cheng, W; Fu, F; Zhao, Z Q.
Afiliación
  • He HW; Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
  • Long Y; Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
  • Chi Y; Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
  • Yuan SY; Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
  • Zhou X; Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
  • Su LX; Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
  • Cheng W; Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
  • Fu F; College of Biomedical Engineering, Military Medical University of Air Force, Xi'an 710032, China.
  • Zhao ZQ; College of Biomedical Engineering, Military Medical University of Air Force, Xi'an 710032, China.
Zhonghua Yi Xue Za Zhi ; 101(15): 1097-1101, 2021 Apr 20.
Article en Zh | MEDLINE | ID: mdl-33878839
Bedside hypertonic saline-contrast electrical impedance tomography (EIT) method for lung perfusion evaluation has several advantages of bedside, simple, noninvasive and radiation-free. For a long time, EIT perfusion image of hypertonic saline was mostly limited to animal experiments, and related clinical research is in the ascendant. This technical specification for clinical application is reached based on our previous researches, review of literatures in this field. The purpose of this technical specification is to facilitate the unified and standardized use of hypertonic saline-contrast EIT technology for regional lung perfusion, to evaluate the safety and quality control of the technology, and to unify the results.