Your browser doesn't support javascript.
loading
REPEATABILITY OF MACULAR MICROVASCULATURE MEASUREMENTS USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY ACCORDING TO TEAR BREAKUP TIME IN DRY EYE DISEASE.
Lee, Woo Hyuk; Lim, Hyung-Bin; Kim, Jaeyoung; Ryu, Cheon Kuk; Shin, Yong-Il; Kim, Jung-Yeul.
Afiliación
  • Lee WH; Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Republic of Korea ; and.
  • Lim HB; Department of Ophthalmology, Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea.
  • Kim J; Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Republic of Korea ; and.
  • Ryu CK; Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Republic of Korea ; and.
  • Shin YI; Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Republic of Korea ; and.
  • Kim JY; Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Republic of Korea ; and.
Retina ; 41(11): 2301-2309, 2021 Nov 01.
Article en En | MEDLINE | ID: mdl-33830961
PURPOSE: It is hypothesized that an unstable tear film would affect the quality and repeatability of optical coherence tomography angiography (OCTA). Therefore, OCTA repeatability according to tear break-up time (TBUT) was compared. METHODS: The 3 × 3 OCTA was performed twice and, the eyes were divided into 3 groups according to the TBUT (Group 1: TBUT ≤ 5 seconds, 43 eyes; Group 2: 5 seconds < TBUT ≤ 10 seconds, 35 eyes; Group 3: TBUT > 10 seconds, 34 eyes). The intraclass correlation coefficient, coefficient of variation, and test-retest SD were calculated and compared. RESULTS: The signal strengths of OCTA were 9.1 ± 1.2, 9.5 ± 0.8, and 9.5 ± 0.8 in each group from Groups 1, 2, and 3, respectively, which showed significant difference (P = 0.049). The intraclass correlation coefficient of vessel density were 0.733, 0.840, and 0.974 in Groups 1 to 3, respectively, and the values increased in the order of Groups 1, 2, and 3. The coefficient of variation were 6.41 ± 6.09, 3.29 ± 2.22, and 1.30 ± 1.17, and the test-retest SD were 0.83 ± 0.70, 0.47 ± 0.31, and 0.19 ± 0.17 in Groups 1, 2, and 3, respectively. The coefficient of variation and test-retest SD values decreased in the order of Groups 1, 2, and 3, and showed a significant difference (all, P < 0.05). CONCLUSION: The repeatability of OCTA tended to decrease with a shorter TBUT. When the TBUT is <5 seconds, care must be taken to interpret the OCTA results correctly.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vasos Retinianos / Lágrimas / Angiografía con Fluoresceína / Síndromes de Ojo Seco / Tomografía de Coherencia Óptica / Microvasos Tipo de estudio: Observational_studies / Prognostic_studies Aspecto: Patient_preference Límite: Adult / Female / Humans / Male Idioma: En Revista: Retina Año: 2021 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vasos Retinianos / Lágrimas / Angiografía con Fluoresceína / Síndromes de Ojo Seco / Tomografía de Coherencia Óptica / Microvasos Tipo de estudio: Observational_studies / Prognostic_studies Aspecto: Patient_preference Límite: Adult / Female / Humans / Male Idioma: En Revista: Retina Año: 2021 Tipo del documento: Article Pais de publicación: Estados Unidos