Your browser doesn't support javascript.
loading
Effect of non-Newtonian fluid rheology on an arterial bypass graft: A numerical investigation guided by constructal design.
Dutra, R F; Zinani, F S F; Rocha, L A O; Biserni, C.
Afiliación
  • Dutra RF; Mechanical Engineering Graduate Program, Universidade do Vale do Rio dos Sinos, 93022-750, São Leopoldo, Brazil.
  • Zinani FSF; Mechanical Engineering Graduate Program, Universidade do Vale do Rio dos Sinos, 93022-750, São Leopoldo, Brazil.
  • Rocha LAO; Mechanical Engineering Graduate Program, Universidade do Vale do Rio dos Sinos, 93022-750, São Leopoldo, Brazil.
  • Biserni C; Department of Industrial Engineering (DIN), School of Engineering and Architecture, Alma Mater Studiorum - University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy. Electronic address: cesare.biserni@unibo.it.
Comput Methods Programs Biomed ; 201: 105944, 2021 Apr.
Article en En | MEDLINE | ID: mdl-33535083
In post-operative scenarios of arterial graft surgeries to bypass coronary artery stenosis, fluid dynamics plays a crucial role. Problems such as intimal hyperplasia have been related to fluid dynamics and wall shear stresses near the graft junction. This study focused on the question of the use of Newtonian and non-Newtonian models to represent blood in this type of problem in order to capture important flow features, as well as an analysis of the performance of geometry from the view of Constructive Theory. The objective of this study was to investigate the effects rheology on the steady-state flow and on the performance of a system consisting of an idealized version of a partially obstructed coronary artery and bypass graft. The Constructal Design Method was employed with two degrees of freedom: the ratio between bypass and artery diameters and the junction angle at the bypass inlet. The flow problem was solved numerically using the Finite Volume Method with blood modeled employing the Carreau equation for viscosity. The Computational Fluid Dynamics model associated with the Sparse Grid method generated eighteen response surfaces, each representing a severe stenosis degree of 75% for specific combinations of rheological parameters, dimensionless viscosity ratio, Carreau number and flow index at two distinct Reynolds numbers of 150 and 250. There was a considerable dependence of the pressure drop on rheological parameters. For the two Reynolds numbers studied, the Newtonian case presented the lowest value of the dimensionless pressure drop, suggesting that the choice of applying Newtonian blood may underestimate the value of pressure drop in the system by about 12.4% (Re =150) and 7.8% (Re = 250). Even so, results demonstrated that non-Newtonian rheological parameters did not influence either the shape of the response surfaces or the optimum bypass geometry, which consisted of a diameter ratio of 1 and junction angle of 30°. However, the viscosity ratio and the flow index had the greatest impact on pressure drop, recirculation zones and wall shear stress. Rheological parameters also affected the recirculation zones downstream of stenosis, where intimal hyperplasia is more prevalent. Newtonian and most non-Newtonian results had similar wall shear stresses, except for the non-Newtonian case with high viscosity ratio. In the view of Constructal Design, the geometry of best performance was independent of the rheological model. However, rheology played an important role on pressure drop and flow dynamics, allowing the prediction of recirculation zones that were not captured by a Newtonian model.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vasos Coronarios / Hidrodinámica Tipo de estudio: Prognostic_studies Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2021 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Irlanda

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vasos Coronarios / Hidrodinámica Tipo de estudio: Prognostic_studies Idioma: En Revista: Comput Methods Programs Biomed Asunto de la revista: INFORMATICA MEDICA Año: 2021 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Irlanda