Your browser doesn't support javascript.
loading
Use of Intraoperative Computed Tomography Improves Outcome of Minimally Invasive Transforaminal Lumbar Interbody Fusion: A Single-Center Retrospective Cohort Study.
Venier, Alice; Croci, Davide; Robert, Thomas; Distefano, Daniela; Presilla, Stefano; Scarone, Pietro.
Afiliación
  • Venier A; Department of Neurosurgery, Neurocenter of Southern Switzerland, Lugano, Switzerland.
  • Croci D; Department of Neurosurgery, Neurocenter of Southern Switzerland, Lugano, Switzerland.
  • Robert T; Department of Neurosurgery, Neurocenter of Southern Switzerland, Lugano, Switzerland; Facoltà di scienze biomediche, Università della Svizzera italiana, Lugano, Switzerland.
  • Distefano D; Department of Neuroradiology, Neurocenter of Southern Switzerland, Lugano, Switzerland.
  • Presilla S; Medical Physics Service, Ente Ospedaliero Cantonale, Bellinzona, Switzerland.
  • Scarone P; Department of Neurosurgery, Neurocenter of Southern Switzerland, Lugano, Switzerland. Electronic address: pietro.scarone@eoc.ch.
World Neurosurg ; 148: e572-e580, 2021 04.
Article en En | MEDLINE | ID: mdl-33482416
OBJECTIVE: To provide data about surgical workflow, accuracy, complications, radiation exposure, and learning curve effect in patients who underwent minimally invasive (MIS) transforaminal lumbar interbody fusion with navigation coupled with mobile intraoperative computed tomography. METHODS: A retrospective analysis was performed of data from consecutive patients who underwent single- or double-level MIS transforaminal lumbar interbody fusion at a single institution; mobile intraoperative computed tomography combined with a navigation system was used as the sole intraoperative imaging method to place pedicular screws; decompression and interbody fusion were performed through a 22-mm tubular retractor. Clinical data, perioperative complications, accuracy of pedicular screw placement, and radiation exposure were analyzed. A learning curve effect on surgical time and accuracy was assessed. RESULTS: A total of 408 screws in 100 patients were analyzed. In all cases, spinal navigation allowed for identification of pedicular trajectories and greatly facilitated nerve root decompression through the MIS approach. Overall accuracy according to Heary classification was 95.3%. Nineteen screws (4.7%) presented a minor lateral breach (<2 mm), not clinically significant. Surgical time, blood loss, and patient radiation exposure compared favorably with reported values from other series using three-dimensional navigation. A learning curve effect on surgical time, but not on screw accuracy, was identified. CONCLUSIONS: MIS transforaminal lumbar interbody fusion can now be performed without any radiation exposure to the surgeon and operating room staff, with almost absolute accuracy during screw positioning and tubular decompression. A learning curve effect on surgical time, but not on overall screw accuracy, may be expected.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fusión Vertebral / Tomografía Computarizada por Rayos X / Monitoreo Intraoperatorio / Procedimientos Quirúrgicos Mínimamente Invasivos / Vértebras Lumbares Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: World Neurosurg Asunto de la revista: NEUROCIRURGIA Año: 2021 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fusión Vertebral / Tomografía Computarizada por Rayos X / Monitoreo Intraoperatorio / Procedimientos Quirúrgicos Mínimamente Invasivos / Vértebras Lumbares Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: World Neurosurg Asunto de la revista: NEUROCIRURGIA Año: 2021 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Estados Unidos