Your browser doesn't support javascript.
loading
X-ray dose reduction using additional copper filtration for dental cone beam CT.
Kuramoto, Taku; Takarabe, Shinya; Shiotsuki, Kenshi; Shibayama, Yusuke; Hamasaki, Hiroshi; Akamine, Hiroshi; Okamura, Kazutoshi; Chikui, Toru; Kato, Toyoyuki; Yoshiura, Kazunori.
Afiliación
  • Kuramoto T; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan. Electronic address: t.kura13@gmail.com.
  • Takarabe S; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan; Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Japan.
  • Shiotsuki K; Medical Technology Department, Oita University Hospital, 1-1 Idaigaoka, Hasama-cho, Yufu-shi, Oita 879-5593, Japan.
  • Shibayama Y; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
  • Hamasaki H; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
  • Akamine H; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
  • Okamura K; Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Japan.
  • Chikui T; Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Japan.
  • Kato T; Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
  • Yoshiura K; Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Japan.
Phys Med ; 81: 302-307, 2021 Jan.
Article en En | MEDLINE | ID: mdl-33349541

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Cobre Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2021 Tipo del documento: Article Pais de publicación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Cobre Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2021 Tipo del documento: Article Pais de publicación: Italia