Your browser doesn't support javascript.
loading
Phakic intraocular lens: Getting the right size.
Deshpande, Kalyaani; Shroff, Rushad; Biswas, Partha; Kapur, Kamal; Shetty, Naren; Koshy, Ann Sarah; Khamar, Pooja.
Afiliación
  • Deshpande K; Department of Cataract and Refractive Surgery, Mumbai Eye, Brain and Spine Clinic, Mumbai, Maharashtra, India.
  • Shroff R; Department of Cataract, Cornea, and Refractive Surgery, Shroff Eye Centre, New Delhi, India.
  • Biswas P; Department of Cataract and Refractive Surgery, Director, B B Eye Foundation, Kolkata, West Bengal, India.
  • Kapur K; Department of Cataract and Refractive Surgery, Director, Sharp Sight Laser Centre Pvt Ltd, New Delhi, India.
  • Shetty N; Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
  • Koshy AS; Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
  • Khamar P; Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
Indian J Ophthalmol ; 68(12): 2880-2887, 2020 Dec.
Article en En | MEDLINE | ID: mdl-33229663
Phakic intraocular lenses (IOL) are a boon for patients who want spectacle independence but are unable to get refractive correction through laser platforms due to high refractive error or certain corneal contraindications. Phakic IOL's (PIOL) have their own set of complications and challenges, the most important being getting the sizing right. This paper attempts to solve the problem of accurate sizing of PIOL's. Parameters needed for calculating the ideal size of PIOL's have been studied in a step by step manner using all possible tools depending upon the availability and preference of the surgeon. The pros and cons of using a particular tool for measurements have been highlighted along with illustrative case examples to help surgeons who are starting PIOL implantation surgery.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Errores de Refracción / Lentes Intraoculares Fáquicas / Lentes Intraoculares Límite: Humans Idioma: En Revista: Indian J Ophthalmol Año: 2020 Tipo del documento: Article País de afiliación: India Pais de publicación: India

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Errores de Refracción / Lentes Intraoculares Fáquicas / Lentes Intraoculares Límite: Humans Idioma: En Revista: Indian J Ophthalmol Año: 2020 Tipo del documento: Article País de afiliación: India Pais de publicación: India