Your browser doesn't support javascript.
loading
Fast, Miniaturized, Real-Time Unit for Sampling, Modulation, and Separation in Detection of Hazardous Chemicals.
Pallis, George C; Psarras, George P; Vamvakari, Julia; Kuula, Matti J; Kiljunen, Harri; Hakulinen, Hanna; Vanninen, Paula.
Afiliación
  • Pallis GC; Advanced Technology Innovation Centre, T4i Engineering Ltd., 5 Oakwood Drive, LE11 3QF Loughborough, United Kingdom.
  • Psarras GP; Advanced Technology Innovation Centre, T4i Engineering Ltd., 5 Oakwood Drive, LE11 3QF Loughborough, United Kingdom.
  • Vamvakari J; Advanced Technology Innovation Centre, T4i Engineering Ltd., 5 Oakwood Drive, LE11 3QF Loughborough, United Kingdom.
  • Kuula MJ; VERIFIN, Finnish Institute for Verification of the Chemical Weapons Convention, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014 Helsinki, Finland.
  • Kiljunen H; VERIFIN, Finnish Institute for Verification of the Chemical Weapons Convention, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014 Helsinki, Finland.
  • Hakulinen H; VERIFIN, Finnish Institute for Verification of the Chemical Weapons Convention, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014 Helsinki, Finland.
  • Vanninen P; VERIFIN, Finnish Institute for Verification of the Chemical Weapons Convention, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014 Helsinki, Finland.
Anal Chem ; 92(21): 14589-14593, 2020 11 03.
Article en En | MEDLINE | ID: mdl-33080133
A sampling, modulation, and separation (SMS) unit was tested for detection of hazardous chemicals. The SMS unit, designed and developed for on-site sampling and analysis, consists of a dynamic inlet system coupled with a fast, miniaturized gas chromatograph (GC). Feasibility of the SMS unit was evaluated together with a hazardous chemical vapor generator. The performance of the SMS unit was tested with automated thermal desorption after SMS to collect samples for GC-mass spectrometry (GC-MS) measurements. Detection of sarin nerve agent was verified. Additionally, the vapor generator was connected to the SMS unit, which was hyphenated with a photoionization detector (PID), thus creating a fast GC-PID system. This system gave a positive response for degradation products of sulfur mustard, thereby indicating suitability of the SMS-PID unit for field drone applications.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Sustancias Peligrosas / Miniaturización Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2020 Tipo del documento: Article País de afiliación: Reino Unido Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Sustancias Peligrosas / Miniaturización Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2020 Tipo del documento: Article País de afiliación: Reino Unido Pais de publicación: Estados Unidos