Your browser doesn't support javascript.
loading
Evaluation of a Fully Automatic Measurement of Short-Term Variability of Repolarization on Intracardiac Electrograms in the Chronic Atrioventricular Block Dog.
Smoczynska, Agnieszka; Sprenkeler, David J; Aranda, Alfonso; Beekman, Jet D M; Bossu, Alexandre; Dunnink, Albert; Wijers, Sofieke C; Stegemann, Berthold; Meine, Mathias; Vos, Marc A.
Afiliación
  • Smoczynska A; Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Sprenkeler DJ; Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Aranda A; Medtronic Bakken Research Center, Maastricht, Netherlands.
  • Beekman JDM; Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Bossu A; Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Dunnink A; Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Wijers SC; Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Stegemann B; Medtronic Bakken Research Center, Maastricht, Netherlands.
  • Meine M; Department of Cardiology, University Medical Center Utrecht, Utrecht, Netherlands.
  • Vos MA; Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
Front Physiol ; 11: 1005, 2020.
Article en En | MEDLINE | ID: mdl-32973549

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Front Physiol Año: 2020 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Front Physiol Año: 2020 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Suiza