Diagnosis of Varroosis Based on Bee Brood Samples Testing with Use of Semiconductor Gas Sensors.
Sensors (Basel)
; 20(14)2020 Jul 19.
Article
en En
| MEDLINE
| ID: mdl-32707688
Varroosis is a dangerous and difficult to diagnose disease decimating bee colonies. The studies conducted sought answers on whether the electronic nose could become an effective tool for the efficient detection of this disease by examining sealed brood samples. The prototype of a multi-sensor recorder of gaseous sensor signals with a matrix of six semiconductor gas sensors TGS 823, TGS 826, TGS 832, TGS 2600, TGS 2602, and TGS 2603 from FIGARO was tested in this area. There were 42 objects belonging to 3 classes tested: 1st class-empty chamber (13 objects), 2nd class-fragments of combs containing brood sick with varroosis (19 objects), and 3rd class-fragments of combs containing healthy sealed brood (10 objects). The examination of a single object lasted 20 min, consisting of the exposure phase (10 min) and the sensor regeneration phase (10 min). The k-th nearest neighbors algorithm (kNN)-with default settings in RSES tool-was successfully used as the basic classifier. The basis of the analysis was the sensor reading value in 270 s with baseline correction. The multi-sensor MCA-8 gas sensor signal recorder has proved to be an effective tool in distinguishing between brood suffering from varroosis and healthy brood. The five-time cross-validation 2 test (5 × CV2 test) showed a global accuracy of 0.832 and a balanced accuracy of 0.834. Positive rate of the sick brood class was 0.92. In order to check the overall effectiveness of baseline correction in the examined context, we have carried out additional series of experiments-in multiple Monte Carlo Cross Validation model-using a set of classifiers with different metrics. We have tested a few variants of the kNN method, the Naïve Bayes classifier, and the weighted voting classifier. We have verified with statistical tests the thesis that the baseline correction significantly improves the level of classification. We also confirmed that it is enough to use the TGS2603 sensor in the examined context.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Semiconductores
/
Abejas
/
Varroidae
/
Gases
Tipo de estudio:
Diagnostic_studies
/
Prognostic_studies
Límite:
Animals
Idioma:
En
Revista:
Sensors (Basel)
Año:
2020
Tipo del documento:
Article
País de afiliación:
Polonia
Pais de publicación:
Suiza