Measurement uncertainty as a universal concept: can it be universally applicable in routine laboratory practice?
Milinkovic, Neda; Jovicic, Snezana; Ignjatovic, Svetlana.
Afiliación
  • Milinkovic N; Department of Medical Biochemistry, Laboratory for Medical Biochemistry Analysis, University of Belgrade-Faculty of Pharmacy, Belgrade, Serbia.
  • Jovicic S; Department of Medical Biochemistry, Laboratory for Medical Biochemistry Analysis, University of Belgrade-Faculty of Pharmacy, Belgrade, Serbia.
  • Ignjatovic S; Center for Medical Biochemistry, Clinical Center of Serbia, Belgrade, Serbia.
Crit Rev Clin Lab Sci ; 58(2): 101-112, 2021 03.
Article en En | MEDLINE | ID: mdl-32672116
Measurement uncertainty (MU) of results is one of the basic recommended and accepted statistical methods in laboratory medicine, with which analytical and clinical evaluation of laboratory test quality is assessed. Literature data indicate that the calculation of MU is not a simple process, but that its assessment in daily laboratory practice should be reduced to routine and simple presentation, understandable to both laboratory professionals and physicians. In order to achieve this, it is necessary to understand the purpose of the test for which MU is to be determined. Various suggestions have been given for presentation of MU as a quantitative indicator of the quality of the final measurement result in the medical laboratory. Although MU refers to the final measurement result, this metrological concept reflects the entire laboratory measurement process. The data on estimated MU is used to interpret the measured numerical result, and represents quantitatively the quality of the measurement itself, i.e. how different are the results of multiple measurements of the analyte of interest in the same sample, as well as whether the method of determination itself is subjected to significant random and systematic deviation. Initially, in the metrological concept, the MU is viewed in relation to the true value of the analyte of interest. However, the true value of the analyte measured in the biological fluid matrix of the study population cannot be known. It is therefore considered the closest value obtained by the perfect method, for which the bias and inaccuracy, as measures of systematic and random error, are equal to zero, which is practically impossible to achieve in routine laboratory practice. Although current standards require accredited medical laboratories to estimate MU, none of these guidelines provide clear guidance on how this can be achieved in daily laboratory work. This review examines literary data and documents dealing with MU issues, but also highlights what additional terms and data should be considered when interpreting MU. This paper ultimately draws attention, and once again points out, that a simpler solution is needed for this universal concept to be formally and universally applicable in routine laboratory medicine practice.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas de Laboratorio Clínico / Laboratorios Tipo de estudio: Diagnostic_studies / Guideline Límite: Humans Idioma: En Revista: Crit Rev Clin Lab Sci Asunto de la revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2021 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas de Laboratorio Clínico / Laboratorios Tipo de estudio: Diagnostic_studies / Guideline Límite: Humans Idioma: En Revista: Crit Rev Clin Lab Sci Asunto de la revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2021 Tipo del documento: Article Pais de publicación: Reino Unido