Your browser doesn't support javascript.
loading
Comprehensive Blood Coagulation Profiling in Patients Using iCoagLab: Comparison Against Thromboelastography.
Tripathi, Markandey M; Tshikudi, Diane M; Hajjarian, Zeinab; Hack, Dallas C; Van Cott, Elizabeth M; Nadkarni, Seemantini K.
Afiliación
  • Tripathi MM; Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States.
  • Tshikudi DM; Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States.
  • Hajjarian Z; Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States.
  • Hack DC; Department of Neurosurgery, School of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States.
  • Van Cott EM; Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States.
  • Nadkarni SK; Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States.
Thromb Haemost ; 120(7): 1116-1127, 2020 Jul.
Article en En | MEDLINE | ID: mdl-32572866
Delayed identification of coagulopathy and bleeding increases the risk of organ failure and death in hospitalized patients. Timely and accurate identification of impaired coagulation at the point-of-care can proactively identify bleeding risk and guide resuscitation, resulting in improved outcomes for patients. We test the accuracy of a novel optical coagulation sensing approach, termed iCoagLab, for comprehensive whole blood coagulation profiling and investigate its diagnostic accuracy in identifying patients at elevated bleeding risk. Whole blood samples from patients (N = 270) undergoing conventional coagulation testing were measured using the iCoagLab device. Recalcified and kaolin-activated blood samples were loaded in disposable cartridges and time-varying intensity fluctuation of laser speckle patterns were measured to quantify the clot viscoelastic modulus during coagulation. Coagulation parameters including the reaction time (R), clot progression time (K), clot progression rate (α), and maximum clot strength (MA) were derived from clot viscoelasticity traces and compared with mechanical thromboelastography (TEG). In all patients, a good correlation between iCoagLab- and TEG-derived parameters was observed (p < 0.001). Multivariate analysis showed that iCoagLab-derived parameters identified bleeding risk with sensitivity (94%) identical to, and diagnostic accuracy (89%) higher than TEG (87%). The diagnostic specificity of iCoagLab (77%) was significantly higher than TEG (69%). By rapidly and comprehensively permitting blood coagulation profiling the iCoagLab innovation is likely to advance the capability to identify patients with elevated risk for bleeding, with the ultimate goal of preventing life-threatening hemorrhage.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tromboelastografía / Coagulación Sanguínea / Pruebas de Coagulación Sanguínea / Pruebas en el Punto de Atención / Hemorragia Tipo de estudio: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Thromb Haemost Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tromboelastografía / Coagulación Sanguínea / Pruebas de Coagulación Sanguínea / Pruebas en el Punto de Atención / Hemorragia Tipo de estudio: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Thromb Haemost Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Alemania