Your browser doesn't support javascript.
loading
Hyperspectral analysis for perioperative perfusion monitoring-a clinical feasibility study on free and pedicled flaps.
Thiem, D G E; Frick, R W; Goetze, E; Gielisch, M; Al-Nawas, B; Kämmerer, P W.
Afiliación
  • Thiem DGE; Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Mainz, Augustusplatz 2, 55131, Mainz, Germany. daniel.thiem@unimedizin-mainz.de.
  • Frick RW; Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Mainz, Augustusplatz 2, 55131, Mainz, Germany.
  • Goetze E; Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Mainz, Augustusplatz 2, 55131, Mainz, Germany.
  • Gielisch M; Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Mainz, Augustusplatz 2, 55131, Mainz, Germany.
  • Al-Nawas B; Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Mainz, Augustusplatz 2, 55131, Mainz, Germany.
  • Kämmerer PW; Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, Seoul, Korea.
Clin Oral Investig ; 25(3): 933-945, 2021 Mar.
Article en En | MEDLINE | ID: mdl-32556663
OBJECTIVES: In reconstructive surgery, flap monitoring is crucial for early identification of perfusion problems. Using hyperspectral imaging (HSI), this clinical study aimed to develop a non-invasive, objective approach for perfusion monitoring of free and pedicled flaps. MATERIAL AND METHODS: HSI of 22 free (FF) and 8 pedicled flaps (PF) in 30 patients was recorded over time. Parameters assessed were tissue oxygenation/superficial perfusion (0-1 mm) (StO2 (0-100%)), near-infrared perfusion/deep perfusion (0-4 mm) (NIR (0-100)), distribution of haemoglobin (THI (0-100)), and water (TWI (0-100)). Measurements up to 72 h were correlated to clinical assessment. RESULTS: Directly after flap inset, mean StO2 was significantly higher in FF (70.3 ± 13.6%) compared with PF 56.2 ± 14.2% (p = 0.05), whereas NIR, THI, and TWI were similar (NIR_p = 0.82, THI_p = 0.97, TWI_p = 0.27). After 24 h, StO2, NIR, THI, and TWI did not differ between FF and PF. After 48 h, StO2, NIR, and TWI did not differ between FF and PF whereas THI was significantly increased in FF compared with PF(p = 0.001). In three FF, perfusion decreased clinically and in HSI, 36(1), 40(2), 5(3), and 61(3) h after flap inset which was followed by prompt intervention. CONCLUSIONS: StO2 < 40%, NIR < 25/100, and THI < 40/100 indicated arterial occlusion, whereas venous problems revealed an increase of THI. In comparison with FF, perfusion parameters of PF were decreased after flap transfer but remained similar to FF later on. CLINICAL RELEVANCE: HSI provides objective and non-invasive perfusion monitoring after flap transplantation in accordance to the clinical situation. With HSI, signs of deterioration can be detected hours before clinical diagnosis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procedimientos de Cirugía Plástica / Imágenes Hiperespectrales Límite: Humans Idioma: En Revista: Clin Oral Investig Asunto de la revista: ODONTOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procedimientos de Cirugía Plástica / Imágenes Hiperespectrales Límite: Humans Idioma: En Revista: Clin Oral Investig Asunto de la revista: ODONTOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania