Impact of a quality control circle on the incidence of catheter-associated urinary tract infection: An interrupted time series analysis.
Zhong, Xiao; Xiao, Li-Hua; Wang, Dong-Li; Yang, Shan-Wen; Mo, Lan-Fang; He, Lan-Fang; Wu, Qing-Fei; Chen, Yan-Wei; Luo, Xiao-Feng.
Afiliación
  • Zhong X; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China. Electronic address: 187197283@qq.com.
  • Xiao LH; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • Wang DL; Department of Nosocomial Infection Control, Inspection Center, Guangming District Center for Disease Control and Prevention, Shenzhen, Guangdong, China.
  • Yang SW; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • Mo LF; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • He LF; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • Wu QF; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • Chen YW; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • Luo XF; Department of Nosocomial Infection Control, Shenzhen Hospital, University of Chinese Academy of Sciences, Shenzhen, Guangdong, China.
Am J Infect Control ; 48(10): 1184-1188, 2020 10.
Article en En | MEDLINE | ID: mdl-32070630
BACKGROUND: To report a quality control circle (QCC) activity on the theme of reducing the incidence of catheter-associated urinary tract infection (CAUTI), and used an interrupted time series analysis to evaluate the impact of the QCC. METHODS: In a general tertiary hospital in Shenzhen, China, we carried out a QCC activity with the theme of reducing CAUTI from April 2017 to December 2017. Before the QCC, we carried out the routine measures; during the QCC, we implemented usual measures and the countermeasures of QCC, and after the QCC, we performed the routine measures and adhered to the core measures of QCC. The interrupted time series analysis method was used to analyze the changes in the CAUTI incidence during the 3 stages. RESULTS: Before, during, and after the QCC activities, the catheter use ratios and mean indwelling time both had a downward trend; meanwhile, the compliance rate of CAUTI prevention measures showed an upward trend. After the interventions, the CAUTI incidence decreased by 1.317‰ immediately, then gradually decreased by 0.510‰ per month. After the completion of QCC, the CAUTI incidence increased by 0.266‰ immediately and increased by 0.070‰ over time, but the difference was not statistically significant. CONCLUSIONS: The CAUTI incidence is reduced through QCC, providing a useful reference for the prevention of CAUTI and the development of medical quality improvement activities.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones Urinarias / Infección Hospitalaria / Infecciones Relacionadas con Catéteres Tipo de estudio: Incidence_studies / Prognostic_studies / Risk_factors_studies Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Am J Infect Control Año: 2020 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones Urinarias / Infección Hospitalaria / Infecciones Relacionadas con Catéteres Tipo de estudio: Incidence_studies / Prognostic_studies / Risk_factors_studies Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Am J Infect Control Año: 2020 Tipo del documento: Article Pais de publicación: Estados Unidos