Your browser doesn't support javascript.
loading
Toric intraocular lens in asymmetric astigmatism.
Kwitko, Sergio; Marafon, Samara Barbara; Stolz, Andressa Prestes.
Afiliación
  • Kwitko S; Ophthalmology Department, Oftalmocentro, Av. Nilo Peçanha, 724/401, Porto Alegre, RS, Brazil.
  • Marafon SB; Ophthalmology Department, Oftalmocentro, Av. Nilo Peçanha, 724/401, Porto Alegre, RS, Brazil. oft.samara@gmail.com.
  • Stolz AP; Ophthalmology Department, Oftalmocentro, Av. Nilo Peçanha, 724/401, Porto Alegre, RS, Brazil.
Int Ophthalmol ; 40(5): 1291-1298, 2020 May.
Article en En | MEDLINE | ID: mdl-31982994
PURPOSE: The aim of this study is to report our results of toric intraocular lens (IOL) implantation in patients with asymmetric astigmatism, its efficacy and safety in reducing the refractive cylinder. METHODS: This is a retrospective cohort study. Patients with asymmetric astigmatism and non-progressive corneal ectasia, unable to fit hard contact lenses, with poor-corrected visual acuity or unsatisfactory spectacles-corrected visual acuity, underwent cataract surgery with toric IOL implantation. The choice of lens was individually after optical biometry examination. All surgeries were performed by a single surgeon, with a 2.75-mm clear cornea self-sealing incision at 130° axis, from December 2008 to December 2015. RESULTS: We evaluated 88 eyes of 69 patients with asymmetric astigmatism: primary, secondary to leucoma, post-radial keratectomy, post-lamellar or penetrating keratoplasty, post-LASIK, post-PRK and due to pterygium. Snellen best-corrected spectacles visual acuity increased from 0.39 ± 0.23 preoperative to 0.80 ± 0.23 postoperative. The average refractive cylinder reduced from 2.32 ± 1.78 D preoperatively to 0.87 ± 1.09 D after surgery (P < .001). Sixty-three eyes out of 88 (71%) had residual refractive cylinder ≤ 1.0 D. CONCLUSION: The favorable efficacy on visual acuity outcomes we have found suggests that toric IOL can be used in cases of asymmetric astigmatism, in order to provide better-corrected vision, less spectacles dependence and an improved quality of vision overall, which is especially important in contact lenses intolerant patients.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Refracción Ocular / Astigmatismo / Agudeza Visual / Edema Corneal / Implantación de Lentes Intraoculares / Lentes Intraoculares Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int Ophthalmol Año: 2020 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Refracción Ocular / Astigmatismo / Agudeza Visual / Edema Corneal / Implantación de Lentes Intraoculares / Lentes Intraoculares Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int Ophthalmol Año: 2020 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Países Bajos