Your browser doesn't support javascript.
loading
Efficacy of visual rehabilitation of patients with pellucid marginal degeneration fitted with SPOT® scleral contact lenses.
Bézé, S; Benoist D'azy, C; Lambert, C; Chiambaretta, F.
Afiliación
  • Bézé S; Ophthalmology service, centre hospitalier régional universitaire Gabriel-Montpied, place Henri-Dunant, 63000 Clermont-Ferrand, France. Electronic address: stevenbeze@gmail.com.
  • Benoist D'azy C; Ophthalmology service, centre hospitalier régional universitaire Gabriel-Montpied, place Henri-Dunant, 63000 Clermont-Ferrand, France.
  • Lambert C; Délégation à la recherche clinique et informatique, centre hospitalier régional universitaire Gabriel-Montpied, place Henri-Dunant, 63000 Clermont-Ferrand, France.
  • Chiambaretta F; Ophthalmology service, centre hospitalier régional universitaire Gabriel-Montpied, place Henri-Dunant, 63000 Clermont-Ferrand, France.
J Fr Ophtalmol ; 43(1): e1-e5, 2020 Jan.
Article en En | MEDLINE | ID: mdl-31836294
PURPOSE: To assess visual improvement in patients with pellucid marginal degeneration (PMD) after fitting with SPOT® scleral contact lenses (Scleral Protection & Ocular Treatment, Laboratoires d'Appareillage Oculaire, Amphion-Les-Bains, France). METHODS: We report a case series of 5 patients with PMD and unsatisfactory refractive correction managed at Clermont-Ferrand university hospital from January to December 2018 fitted with customized SPOT scleral lenses. We assessed the best-corrected visual acuity (BCVA) before and after fitting with SPOT, keratometric data and tolerability of the scleral lenses. RESULTS: Nine eyes of 5 patients aged 51.8±8.47 years were fitted. The BCVA was significantly improved from 0.51 logMAR (±0.39) to 0.04 logMAR (±0.07) (P<0.001). Sixty-six percent of the patients recovered optimal BCVA. No serious adverse event was reported. The presence of whitish deposits and an inordinate amount of manipulation required were the main disadvantages of the lenses. Nevertheless, all the patients considered them to be comfortable. CONCLUSION: Fitting PMD patients who have failed conventional optical devices with SPOT scleral lenses significantly improves BCVA, without serious adverse events, allowing surgery to be deferred even when it appears to be unavoidable.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Baja Visión / Ajuste de Prótesis / Lentes de Contacto / Enfermedades de la Córnea Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Fr Ophtalmol Año: 2020 Tipo del documento: Article Pais de publicación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Baja Visión / Ajuste de Prótesis / Lentes de Contacto / Enfermedades de la Córnea Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Fr Ophtalmol Año: 2020 Tipo del documento: Article Pais de publicación: Francia