Your browser doesn't support javascript.
loading
Characterization of membrane adsorbers used for impurity removal during the continuous purification of monoclonal antibodies.
Trnovec, Helena; Doles, Tibor; Hribar, Gorazd; Furlan, Nebojsa; Podgornik, Ales.
Afiliación
  • Trnovec H; Lek Pharmaceuticals, Technical Development Biosimilars, Technical Research & Development Novartis, Kolodvorska cesta 27, Menges 1234, Slovenia; Faculty for Chemistry and Chemical Technology, University of Ljubljana, Vecna pot 113, Ljubljana 1000, Slovenia.
  • Doles T; Lek Pharmaceuticals, Technical Development Biosimilars, Technical Research & Development Novartis, Kolodvorska cesta 27, Menges 1234, Slovenia.
  • Hribar G; Lek Pharmaceuticals, Technical Development Biosimilars, Technical Research & Development Novartis, Kolodvorska cesta 27, Menges 1234, Slovenia.
  • Furlan N; Lek Pharmaceuticals, Technical Development Biosimilars, Technical Research & Development Novartis, Kolodvorska cesta 27, Menges 1234, Slovenia.
  • Podgornik A; Faculty for Chemistry and Chemical Technology, University of Ljubljana, Vecna pot 113, Ljubljana 1000, Slovenia; COBIK, Tovarniska 26, Ajdovscina 5270, Slovenia. Electronic address: ales.podgornik@fkkt.uni-lj.si.
J Chromatogr A ; 1609: 460518, 2020 Jan 04.
Article en En | MEDLINE | ID: mdl-31563300
A fully continuous, downstream process represents one of the most interesting novel purification approaches in the biosimilars industry, because it would enhance the production output while reducing the costs of complex biopharmaceuticals. Since it generally involves several chromatographic steps, the selection of appropriate chromatographic columns is of utmost importance. In this study we compared several commercially available ion-exchange-membrane adsorbers (NatriFlo®, Sartobind® and Mustang®) for the removal of deoxyribonucleic acid (DNA), host cell proteins (HCPs) and monoclonal antibody aggregates in flow-through mode. Design of Experiments (DoEs) was employed to determine the optimal pH and conductivity conditions. We demonstrated that all the anion-exchange-membrane adsorbers were capable of removing DNA and HCPs from monoclonal antibody mixtures below the required threshold across a wide range of sample pH and conductivity values, and that the HCPs' normalized outlet concentration increases almost linearly with the loading, being independent of the HCPs' concentration. No significant differences in the profile of the adsorbed HCPs with respect to the membrane adsorbers were observed, based on 2D electrophoresis analysis data, although they exhibited different binding capacities. Cation-exchange-membrane adsorbers were also tested for the removal of aggregates. The Yamamoto model was used to determine the number of binding sites and estimate the conductivity range for efficient removal of aggregates, while maintaining a high monoclonal antibody recovery. However, the obtained range had to be further fine-tuned experimentally, due to displacement phenomena. Differences in the trends of binding-site number with a change in the pH value for the tested cation-exchange adsorbers indicate slightly different adsorption mechanisms. To obtain optimal process performance, adjustments to the pH and the conductivity were required between the anion- and cation-exchange steps.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Membranas Artificiales / Anticuerpos Monoclonales Idioma: En Revista: J Chromatogr A Año: 2020 Tipo del documento: Article País de afiliación: Eslovenia Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Membranas Artificiales / Anticuerpos Monoclonales Idioma: En Revista: J Chromatogr A Año: 2020 Tipo del documento: Article País de afiliación: Eslovenia Pais de publicación: Países Bajos