Your browser doesn't support javascript.
loading
Dual-Emissive Metal-Organic Framework as a Fluorescent "Switch" for Ratiometric Sensing of Hypochlorite and Ascorbic Acid.
Zeng, Yong-Nian; Zheng, He-Qi; Gu, Jia-Fang; Cao, Gao-Juan; Zhuang, Wan-E; Lin, Jian-Di; Cao, Rong; Lin, Zu-Jin.
Afiliación
  • Zeng YN; Department of Applied Chemistry, College of Life Sciences , Fujian Agriculture and Forestry University , Fuzhou , Fujian 350002 , People's Republic of China.
  • Zheng HQ; State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter , Chinese Academy of Sciences , Fuzhou 350002 , People's Republic of China.
  • Gu JF; Department of Applied Chemistry, College of Life Sciences , Fujian Agriculture and Forestry University , Fuzhou , Fujian 350002 , People's Republic of China.
  • Cao GJ; State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter , Chinese Academy of Sciences , Fuzhou 350002 , People's Republic of China.
  • Zhuang WE; Department of Chemical Engineering, Zhicheng College , Fuzhou University , Fuzhou , Fujian 350002 , People's Republic of China.
  • Lin JD; Department of Applied Chemistry, College of Life Sciences , Fujian Agriculture and Forestry University , Fuzhou , Fujian 350002 , People's Republic of China.
  • Cao R; Department of Applied Chemistry, College of Life Sciences , Fujian Agriculture and Forestry University , Fuzhou , Fujian 350002 , People's Republic of China.
  • Lin ZJ; Department of Applied Chemistry, College of Life Sciences , Fujian Agriculture and Forestry University , Fuzhou , Fujian 350002 , People's Republic of China.
Inorg Chem ; 58(19): 13360-13369, 2019 Oct 07.
Article en En | MEDLINE | ID: mdl-31503468
The detection of hypochlorite (ClO-) content in tap water is extremely important because excess amounts of hypochlorite can convert into highly toxic species and inadequate amounts of hypochlorite cannot fully kill bacteria and viruses. Although several metal-organic frameworks (MOFs) have been successfully employed as fluorescent sensors for hypochlorite detection, all these sensors are based on single emission that responds to the dose of hypochlorite. Ratiometric sensors are highly desirable, which can improve the sensitivity, accuracy, and reliability via self-calibration. Herein, a nanoscale dual-emission multivariate 5-5-Eu/BPyDC@MOF-253-NH2 was synthesized by sequential mixed-ligand self-assembly and postsynthesis method. Among the two emission bands of 5-5-Eu/BPyDC@MOF-253-NH2, the strong blue emitting derived from ligands is sensitive to hypochlorite, while the red emitting derived from Eu(III) almost keeps invariable. Therefore, 5-5-Eu/BPyDC@MOF-253-NH2 was exploited as a fluorescent ratiometric nanosensor for "on-off" sensing of hypochlorite. Notably, the proposed sensing system showed an excellent performance including fast response (within 15 s), relative high specificity, wide linear range (0.1-30 µM), and low detection limit (0.094 µM). Besides, the suppressed blue emitting was recovered after the addition of ascorbic acid (AA) that consumes ClO- via the redox reaction. Therefore, 5-5-Eu/BPyDC@MOF-253-NH2 was further employed as a fluorescent ratiometric nanosensor for the "on-off-on" sensing of AA. This work represents the first MOF-based fluorescent "switch" for the ratiometric sensing of hypochlorite and the second for ratiometric sensing of AA.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Inorg Chem Año: 2019 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Inorg Chem Año: 2019 Tipo del documento: Article Pais de publicación: Estados Unidos