Your browser doesn't support javascript.
loading
Titanium cage reconstruction of acetabular defects in revision hip arthroplasty results in favourable outcomes: up to 17 years follow-up.
Akel, Ibrahim; Caglar, Ömür; Tokgözoglu, A Mazhar; Atilla, Bülent.
Afiliación
  • Akel I; Faculty of Health Sciences, Izmir University of Economics, Balçova, Izmir, Turkey.
  • Caglar Ö; Izmir Kent Hosptal, Orthopaedics and Traumatology, Çigli, Izmir, Turkey.
  • Tokgözoglu AM; Orthopaedics and Traumatology Department, Hacettepe University, Ankara, Turkey.
  • Atilla B; Orthopaedics and Traumatology Department, Hacettepe University, Ankara, Turkey.
Hip Int ; 30(5): 617-621, 2020 Sep.
Article en En | MEDLINE | ID: mdl-31185746
INTRODUCTION: Titanium cages are valuable implant solutions in management of severe acetabular defects during total hip revisions. We aimed to report clinical and radiological results of our cases in which we used titanium cages for reconstruction of acetabular defects. METHODS: Patients underwent titanium cage reconstruction and bone grafting for their acetabular defects with minimum 2 year-follow-up are included to the study. Analysis of patient records, modified Hospital for Special Surgery hip score and radiological examinations on plain X-rays were evaluated. Acetabular defects are classified according to Paprosky's classification.Kaplan Meier survival analysis is performed. RESULTS: Fifty-six hips of 54 patients (2 bilateral) aged between 29-79 (mean 57 years ) are followed up for 7.06 years ±3.72 (2-17 years).Five patients required revision surgeries at a mean of 2.6±2.2 years. Kaplan Meier's analysis revealed a survival rate of 91,5 % and mean revision free duration was 15,66±0,56 years.HSS scores of the patients before revision surgery yielded a mean score of 27,9 ± 4,9 (14-38). HSS scores at final follow up showed a significant improvement at a mean score of 45,9 ± 7 (28-56) differences were statistically significant, p<0,001). DISCUSSION: Titanium cages are successful for restoring bone stock in severe acetabular defects. It is critical to pay attention on meticulous bone grafting of the presented defects and obtain good hip mechanics during cage insertion. Mechanical reasons are the leading cause of failure in long term but restoration of the bone stock and improvement in defect severity were regularly observed even in failed cages.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trasplante Óseo / Artroplastia de Reemplazo de Cadera / Prótesis de Cadera / Acetábulo Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Hip Int Año: 2020 Tipo del documento: Article País de afiliación: Turquía Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trasplante Óseo / Artroplastia de Reemplazo de Cadera / Prótesis de Cadera / Acetábulo Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Hip Int Año: 2020 Tipo del documento: Article País de afiliación: Turquía Pais de publicación: Estados Unidos