Nylon 6,6 modified screen printed carbon electrodes as electrochemical sensors for rapid chlorothalonil determination in water samples using differential pulse cathodic stripping voltammetry.
Thanalechumi, Paramalinggam; Mohd Yusoff, Abdull Rahim; Yusop, Zulkifli.
Afiliación
  • Thanalechumi P; a Department of Chemistry, Faculty of Science , Universiti Teknologi Malaysia , UTM Johor Bahru, Malaysia.
  • Mohd Yusoff AR; b Centre for Environment Sustainability and Water Security (IPASA) , Universiti Teknologi Malaysia , UTM Johor Bahru, Malaysia.
  • Yusop Z; a Department of Chemistry, Faculty of Science , Universiti Teknologi Malaysia , UTM Johor Bahru, Malaysia.
J Environ Sci Health B ; 54(4): 294-302, 2019.
Article en En | MEDLINE | ID: mdl-30729855
A newly developed electrochemical sensor for chlorothalonil based on nylon 6,6 film deposited onto screen printed electrode (SPE) with electrochemical modulation of pH at the electrode/solution interface was studied for the first time. Differential pulse cathodic stripping voltammetry (DPCSV) was used to carry out the electrochemical and analytical studies. Experimental parameters such as accumulation potential, initial potential, accumulation time and pH of Britton-Robinson buffer have been optimized. Chlorothalonil gave optimum analytical signal in a medium of 0.04 M Britton-Robinson buffer at pH 6.0. A well-defined reduction peak was observed, at Ep= -0.851 and -0.938 V vs. Ag/AgCl (3.0 M KCl) for both bare SPE and modified SPE, respectively. The peak currents of modified SPE were significantly increased as compared to bare SPE. At the modified SPE, a linear relationship between the peak current and chlorothalonil concentration was obtained in the range from 0.1 to 2.8 × 10-6 M with a detection limit of 1.53 × 10-8 M (S/N= 3). The practical applicability of the newly developed method has been demonstrated on analyses of real water samples. The newly developed sensor shows good reproducibility with RSD of 3.92%. The nylon 6,6 modified SPE showed itself as promising sensor with good selectivity for chlorothalonil determination.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Electroquímica / Electrodos / Nitrilos País/Región como asunto: Asia Idioma: En Revista: J Environ Sci Health B Año: 2019 Tipo del documento: Article País de afiliación: Malasia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Electroquímica / Electrodos / Nitrilos País/Región como asunto: Asia Idioma: En Revista: J Environ Sci Health B Año: 2019 Tipo del documento: Article País de afiliación: Malasia Pais de publicación: Reino Unido