Your browser doesn't support javascript.
loading
Development of a three-wave far-infrared laser interferometry and polarimetry diagnostic system for the C-2W field-reversed configuration plasmas.
Deng, B H; Rouillard, M; Feng, P; Beall, M; Armstrong, S; Castellanos, J; Kinley, J; Leinweber, H K; Ottaviano, A; Settles, G; Snitchler, G; Wells, J; Ziaei, S; Thompson, M.
Afiliación
  • Deng BH; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Rouillard M; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Feng P; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Beall M; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Armstrong S; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Castellanos J; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Kinley J; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Leinweber HK; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Ottaviano A; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Settles G; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Snitchler G; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Wells J; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Ziaei S; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
  • Thompson M; TAE Technologies, Inc., Foothill Ranch, California 92610, USA.
Rev Sci Instrum ; 89(10): 10B109, 2018 Oct.
Article en En | MEDLINE | ID: mdl-30399682
Great advancements in modern field-reversed configuration (FRC) experiments motivated the development of a 14-chord three-wave far infrared (FIR) laser interferometry and polarimetry diagnostic system, which can provide simultaneous high temporal resolution measurements of density and Faraday rotation profiles with high accuracy. The unique challenges facing FIR diagnostics in high beta FRC plasmas are the extremely small (<0.5°) Faraday rotation angles, and severe laser beam refraction effects due to high density gradient and choice of long wavelength. The diagnostic system design and development are described with methods to overcome the challenges, and initial experimental data are also presented.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos