Your browser doesn't support javascript.
loading
Development of periprosthetic bone mass density around the cementless Metha® short hip stem during three year follow up-a prospective radiological and clinical study.
Augustin, Laura; Boller, Sarah; Bobach, Cathrein; Jahnke, Alexander; Ahmed, Gafar Adam; Rickert, Markus; Ishaque, Bernd Alexander.
Afiliación
  • Augustin L; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany.
  • Boller S; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany.
  • Bobach C; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany.
  • Jahnke A; Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstraße 29, 35392, Giessen, Germany.
  • Ahmed GA; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany.
  • Rickert M; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany.
  • Ishaque BA; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany. Bernd.Ishaque@ortho.med.uni-giessen.de.
Int Orthop ; 43(9): 2031-2037, 2019 09.
Article en En | MEDLINE | ID: mdl-30178069
PURPOSE: The purpose of this study was to check the concept of the cementless Metha® short hip stem in order to find out whether proximal physiological load transfer can be achieved. METHODS: Fourty-three patients were included. Epidemiological factors were established. The Harris Hip Score was determined and measurement of bone mass density as well as osteodensitometric and radiological measurements was carried out pre-operatively, post-operatively, and after six, 12, 24, and 36 months. RESULTS: Harris Hip Score improved from 55.9 ± 12.4 pre-operatively to 94.8 ± 8.2 after 36 months (p < 0.001). After initial reduction of bone density in zones 1 and 7 up to six months post-operatively, there was a steady approximation of bone density to the initial values (p < 0.05). CONCLUSION: The Metha® short hip stem shows good clinical results. Furthermore, there is an increase of bone density in the proximal zones 1 and 7 between six and 36 months serving as a sign of physiological load transfer.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoartritis de la Cadera / Oseointegración / Artroplastia de Reemplazo de Cadera / Fémur / Necrosis de la Cabeza Femoral / Prótesis de Cadera Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int Orthop Año: 2019 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoartritis de la Cadera / Oseointegración / Artroplastia de Reemplazo de Cadera / Fémur / Necrosis de la Cabeza Femoral / Prótesis de Cadera Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int Orthop Año: 2019 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania