Continuous improvement of safety in the Intensive Care and Surgical environment according to UNE 179003:2013 standard: 8 years experience. / Mejora continua de la seguridad en el ámbito de un Servicio de Anestesiología y Cuidados Intensivos a través de la certificación según la norma de UNE 179003:2013: 8 años de experiencia.
Cabadas Avión, R; Leal Ruiloba, M S; Muñoz Mella, M A; Vázquez Lima, A; Ojea Cendón, M; Enríquez de Salamanca, I.
Afiliación
  • Cabadas Avión R; Servicio de Anestesiología y Cuidados Intensivos, Hospital Povisa, Vigo, Pontevedra, España. Electronic address: rcabadas@povisa.es.
  • Leal Ruiloba MS; Servicio de Anestesiología y Cuidados Intensivos, Hospital Povisa, Vigo, Pontevedra, España.
  • Muñoz Mella MA; Dirección de enfermería y calidad, Hospital Povisa, Vigo, España.
  • Vázquez Lima A; Servicio de Anestesiología y Cuidados Intensivos, Hospital Povisa, Vigo, Pontevedra, España.
  • Ojea Cendón M; Servicio de Anestesiología y Cuidados Intensivos, Hospital Povisa, Vigo, Pontevedra, España.
  • Enríquez de Salamanca I; Unidad de Calidad, Hospital Povisa, Vigo, Pontevedra, España.
Rev Esp Anestesiol Reanim (Engl Ed) ; 65(9): 486-494, 2018 Nov.
Article en En, Es | MEDLINE | ID: mdl-30153990
INTRODUCTION: The UNE 179003:2013 standard requires compliance with protocols to reduce the risks of patients from adverse events. METHODS: A description is presented of the procedure used in the Hospital Povisa to achieve UNE 179003:2010 certification for the intensive care unit, surgical division, and post-anaesthesia recovery unit (PARU). This was based on a risk management system, focusing on pro-active analysis using failure modes and effects analysis (FMEA) with the description of causes, consequences, risk weighting, and specific risk-minimising measures. A description is also presented of the analysis of reported adverse events (reactive analysis) in the Safety in Anesthesia and Resuscitation (SENSAR) notification system and the measures implemented over an eight-year period. RESULTS: The UNE 179003:2010 certification was obtained in July 2012, and the re-certification was achieved in July 2015. A total of 66 potential risks were established, which were weighted using a risk probability index (RPI), and measures were implemented that reduced this RPI by half. It also reflects the analysis of 1114 events declared in the SENSAR system over the past eight years, allowing for the introduction of 2681 measures, of which 98.4% are fully implemented. CONCLUSION: The application of the risk management methodology allowed (a) to improve safety in the area of action by reducing the risk to which the patients are subject, and (b) to gain certification in the UNE 179003 standard.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gestión de Riesgos / Servicio de Cirugía en Hospital / Certificación / Cuidados Críticos / Mejoramiento de la Calidad / Seguridad del Paciente / Unidades de Cuidados Intensivos / Servicio de Anestesia en Hospital Tipo de estudio: Etiology_studies / Guideline Límite: Humans País/Región como asunto: Europa Idioma: En / Es Revista: Rev Esp Anestesiol Reanim (Engl Ed) Año: 2018 Tipo del documento: Article Pais de publicación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gestión de Riesgos / Servicio de Cirugía en Hospital / Certificación / Cuidados Críticos / Mejoramiento de la Calidad / Seguridad del Paciente / Unidades de Cuidados Intensivos / Servicio de Anestesia en Hospital Tipo de estudio: Etiology_studies / Guideline Límite: Humans País/Región como asunto: Europa Idioma: En / Es Revista: Rev Esp Anestesiol Reanim (Engl Ed) Año: 2018 Tipo del documento: Article Pais de publicación: España