Your browser doesn't support javascript.
loading
Crossed K-Wires Versus Intramedullary Headless Screw Fixation of Unstable Metacarpal Neck Fractures: A Biomechanical Study.
Beutel, Bryan G; Ayalon, Omri; Kennedy, Oran D; Lendhey, Matin; Capo, John T; Melamed, Eitan.
Afiliación
  • Beutel BG; The Hand Surgery Center, Mount Sinai Beth Israel, New York, NY.
  • Ayalon O; Division of Hand Surgery, NYU Langone Orthopedic Hospital, New York, NY.
  • Kennedy OD; Royal College of Surgeons in Ireland, Trinity College, Dublin, Ireland.
  • Lendhey M; Musculoskeletal Research Center, NYU Langone Orthopedic Hospital, New York, NY.
  • Capo JT; Department of Orthopaedics, Jersey City Medical Center, Jersey City, NJ.
  • Melamed E; Division of Hand Surgery, NYU Langone Orthopedic Hospital, New York, NY.
Iowa Orthop J ; 38: 153-157, 2018.
Article en En | MEDLINE | ID: mdl-30104939
Background: Intramedullary headless screw (IMHS) has shown promise as an alternative to other fixation devices for metacarpal neck fractures. The purpose of this study was to assess the biomechanical performance of IMHS versus the commonly-used crossed K-wire technique. We hypothesized that IMHS fixation provides superior stability to K-wires. Methods: A metacarpal neck fracture model in 23 human cadaveric metacarpals was created. The specimens were divided into two groups based upon fixation method: Group 1, 3 mm intramedullary headless screw; and Group 2, 0.045 inch crossed K-wires. A cantilever bending model was used to assess load-to-failure (LTF), maximum displacement, energy absorption, and stiffness. Results: The mean LTF was 70.6 ± 30.1 N for IMHS and 97.5 ± 34.7 N for crossed K-wires. Mean stiffness was 11.3 ± 3.4 N/mm and 17.7 ± 7.8 N/mm for IMHS and crossed K-wires, respectively. The mean maximum displacement was 20.2 ± 4.6 mm for IMHS and 24.1 ± 3.7 mm for crossed K-wires. Moreover, mean energy absorption was 778.3 ± 528.9 Nmm and 1095.9 ± 454.4 Nmm, respectively, for IMHS and crossed K-wires. Crossed K-wires demonstrated significantly higher stiffness and maximum displacement than IMHS (p < 0.05). Conclusions: IMHS fixation of unstable metacarpal neck fractures offers less stability compared to crossed K-wires when loaded in bending. Clinical Relevance: Crossed K-wires offer superior stability for the treatment of metacarpal neck fractures. These results reveal that IMHS fixation is less favorable biomechanically and should be cautiously selected with regards to fracture stability.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tornillos Óseos / Hilos Ortopédicos / Huesos del Metacarpo / Fracturas Óseas / Fijación Interna de Fracturas Límite: Humans Idioma: En Revista: Iowa Orthop J Asunto de la revista: ORTOPEDIA Año: 2018 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tornillos Óseos / Hilos Ortopédicos / Huesos del Metacarpo / Fracturas Óseas / Fijación Interna de Fracturas Límite: Humans Idioma: En Revista: Iowa Orthop J Asunto de la revista: ORTOPEDIA Año: 2018 Tipo del documento: Article Pais de publicación: Estados Unidos