Your browser doesn't support javascript.
loading
Selective Monitoring of Oxyanion Mixtures by a Flow System with Raman Detection.
Zapata, Félix; Ortega-Ojeda, Fernando; García-Ruiz, Carmen; González-Herráez, Miguel.
Afiliación
  • Zapata F; Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, Madrid 28871, Spain. felix.zapata@uah.es.
  • Ortega-Ojeda F; University Institute of Research in Police Sciences (IUICP), Law Faculty, University of Alcalá, Alcalá de Henares, Madrid 28871, Spain. fernando.ortega@uah.es.
  • García-Ruiz C; Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, Madrid 28871, Spain. carmen.gruiz@uah.es.
  • González-Herráez M; University Institute of Research in Police Sciences (IUICP), Law Faculty, University of Alcalá, Alcalá de Henares, Madrid 28871, Spain. carmen.gruiz@uah.es.
Sensors (Basel) ; 18(7)2018 Jul 08.
Article en En | MEDLINE | ID: mdl-29986534
Raman spectroscopy is a selective detection system scarcely applied for the flow analysis of solutions with the aim of detecting several compounds at once without a previous separation step. This work explores the potential of a portable Raman system in a flow system for the selective detection of a mixture of seven oxyanions (carbonate, sulphate, nitrate, phosphate, chlorate, perchlorate, and thiosulphate). The specific bands of these compounds (symmetric stretching Raman active vibrations of carbonate at 1068 cm−1, nitrate at 1049 cm−1, thiosulphate at 998 cm−1, phosphate at 989 cm−1, sulphate at 982 cm−1, perchlorate at 935 cm−1, and chlorate at 932 cm−1) enabled their simultaneous detection in mixtures. Although the oxyanions’ limit of detection (LOD) was rather poor (in the millimolar range), this extremely simple system is very useful for the single-measurement detection of most of the oxyanions in mixtures, without requiring a previous separation step. In addition, quantitative determination of the desired oxyanion can be performed by means of the corresponding calibration line. These are important advantages for controlling in-line processes in industries like those manufacturing fertilizers, pharmaceuticals, chemicals, or food, among others.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Año: 2018 Tipo del documento: Article País de afiliación: España Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Año: 2018 Tipo del documento: Article País de afiliación: España Pais de publicación: Suiza