Your browser doesn't support javascript.
loading
Long-Term Outcomes After Metal-on-Metal Total Hip Arthroplasty With a 28-mm Head: A 17- to 23-Year Follow-Up Study of a Previous Report.
Moon, Jun-Ki; Kim, Yeesuk; Hwang, Kyu-Tae; Yang, Jae-Hyuk; Oh, Young-Ha; Kim, Young-Ho.
Afiliación
  • Moon JK; Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea.
  • Kim Y; Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea.
  • Hwang KT; Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea.
  • Yang JH; Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea.
  • Oh YH; Department of Pathology, Hanyang University Guri Hospital, Guri, South Korea.
  • Kim YH; Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea.
J Arthroplasty ; 33(7): 2165-2172, 2018 07.
Article en En | MEDLINE | ID: mdl-29656971
BACKGROUND: Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography. METHODS: A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated. RESULTS: The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%). CONCLUSION: MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis Articulares de Metal sobre Metal / Articulación de la Cadera / Prótesis de Cadera Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2018 Tipo del documento: Article País de afiliación: Corea del Sur Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis Articulares de Metal sobre Metal / Articulación de la Cadera / Prótesis de Cadera Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2018 Tipo del documento: Article País de afiliación: Corea del Sur Pais de publicación: Estados Unidos