Safety of lumen-apposing stent with or without coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a retrospective study.
Puga, Manuel; Consiglieri, Claudia F; Busquets, Juli; Pallarès, Natàlia; Secanella, Lluis; Peláez, Nuria; Fabregat, Joan; Castellote, José; Gornals, Joan B.
Afiliación
  • Puga M; Department of Digestive Diseases, Complexo Hospitalario Universitario de Ourense, Ourense, Spain.
  • Consiglieri CF; Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain.
  • Busquets J; Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain.
  • Pallarès N; Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain.
  • Secanella L; Statistics Advisory Service, Bellvitge Biomedical Research Institute (IDIBELL), Barcelona, Spain.
  • Peláez N; Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain.
  • Fabregat J; Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain.
  • Castellote J; Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain.
  • Gornals JB; Hepatology Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain.
Endoscopy ; 50(10): 1022-1026, 2018 10.
Article en En | MEDLINE | ID: mdl-29590668
BACKGROUND: The aim of this study was to evaluate whether the placement of a coaxial double-pigtail plastic stent (DPS) within a lumen-apposing metal stent (LAMS) may improve the safety of endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs). METHODS: This was a retrospective cohort study including patients with PFCs and an indication for transmural drainage. Two strategies (LAMS alone or LAMS plus DPS) were used at the endoscopist's discretion. RESULTS: A total of 41 patients were treated (21 LAMS alone; 20 LAMS plus DPS). The characteristics of the PFCs, and the technical and clinical success rates did not differ between groups. The LAMS alone group had a significantly higher rate of adverse events than the LAMS plus DPS group (42.9 % vs. 10.0 %; P = 0.04). Bleeding was the most frequent adverse event observed. CONCLUSIONS: The addition of a coaxial DPS to LAMS was associated with a lower rate of adverse events in EUS-guided drainage of PFCs.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Páncreas / Seudoquiste Pancreático / Stents / Drenaje / Hemorragia Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Endoscopy Año: 2018 Tipo del documento: Article País de afiliación: España Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Páncreas / Seudoquiste Pancreático / Stents / Drenaje / Hemorragia Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Endoscopy Año: 2018 Tipo del documento: Article País de afiliación: España Pais de publicación: Alemania