Influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output.
Shu-Lan, Chen; Fang-Chen, Lan; Zhen-Shuang, Du; Ya-Ping, Xu; Hui-Ming, Zhao; Cui-Ping, Zeng; Yu, Miao.
Afiliación
  • Shu-Lan C; General Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
  • Fang-Chen L; General Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
  • Zhen-Shuang D; General Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
  • Ya-Ping X; General Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
  • Hui-Ming Z; General Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
  • Cui-Ping Z; General Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China.
  • Yu M; General Surgery Department, The 180th Hospital of Chinese People's Liberation Army, Quanzhou, 362000, Fujian, China. 735854218@qq.com.
Biomed Eng Online ; 17(1): 34, 2018 Mar 16.
Article en En | MEDLINE | ID: mdl-29548292
OBJECTIVE: This study aimed to investigate the influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output (PICCO, made in Germany), and thereby to provide significant references for clinical practice. METHODS: A total of 108 critical patients in stroke intensive care unit were identified. All these participants received transesophageal cardiac color Doppler ultrasound, and within 15 min PICCO equipment was utilized to monitor the relevant parameters, by means of 0 °C calibrating standard solution, and the injection speeds were 2-4, 5-7, and 8-10 s. Besides, the monitoring indicators were as follows, cardiac index, global ejection fraction, global end diastolic volume index. The potential correlations were evaluated between PICCO and transesophageal cardiac color Doppler ultrasound. RESULTS: All the data was available, and the monitored parameters of PICOO at 2-4, 5-7, and 8-10 s were positively correlated with the parameters obtained from transesophageal cardiac color Doppler ultrasound (P < 0.05). Specially, it is worth emphasizing that the best correlation between them could be provided when the injection rate was 2-4 s. CONCLUSION: When the injection rate at 2-4 s, the parameters obtained by PICOO were much closer to that of transesophageal cardiac color Doppler ultrasound. Furthermore, the parameters of PICOO obtained at 2-4 s could better reflect cardiac function of patients.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gasto Cardíaco / Monitoreo Fisiológico Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Biomed Eng Online Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2018 Tipo del documento: Article País de afiliación: China Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gasto Cardíaco / Monitoreo Fisiológico Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Biomed Eng Online Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2018 Tipo del documento: Article País de afiliación: China Pais de publicación: Reino Unido