Your browser doesn't support javascript.
loading
Increased Effectiveness of Microbiological Verification by Concentration-Dependent Neutralization of Sanitizers Used in Poultry Slaughter and Fabrication Allowing Salmonella enterica Survival.
Mohammad, Zahra H; Hasan, Amer A; Kerth, Chris R; Riley, David G; Taylor, T Matthew.
Afiliación
  • Mohammad ZH; Department of Nutrition and Food Science, Texas A & M University, College Station, TX 77843, USA. zahra74@tamu.edu.
  • Hasan AA; Department of Poultry Science, Texas A & M University, College Station, TX 77843, USA. dramir76@yahoo.com.
  • Kerth CR; Department of Animal Science, Texas A & M AgriLife Research, College Station, TX 77843, USA. c-kerth@tamu.edu.
  • Riley DG; Department of Animal Science, Texas A & M AgriLife Research, College Station, TX 77843, USA. david-riley@tamu.edu.
  • Taylor TM; Department of Animal Science, Texas A & M AgriLife Research, College Station, TX 77843, USA. matt_taylor@tamu.edu.
Foods ; 7(3)2018 Mar 03.
Article en En | MEDLINE | ID: mdl-29510486
Sanitizer neutralizers can assist foodborne pathogen detection during routine testing by counteracting sanitizer residues carried over into fluids collected and tested from food samples. This study tested sanitizer-matched neutralizers applied at increasing concentrations to facilitate Salmonella enterica survival following exposure to cetylpyridinium chloride (CPC) or peracetic acid (PAA), identifying minimum required concentrations of neutralizers to facilitate pathogen survival. Salmonella isolates were individually inoculated into a non-selective medium followed immediately by CPC (0.1 to 0.8% v/v) or PAA (0.0125 to 0.2% v/v) application, followed by neutralizers application. CPC was neutralized by lecithin and polysorbate 80, each supplemented into buffered peptone water (BPW) at 0.125 to 2.0X its respective content in Dey-Engley (D/E) neutralizing buffer. PAA was neutralized in BPW supplemented with disodium phosphate, potassium monophosphate, and sodium thiosulfate, each at 0.25 to 3.0X its respective concentration in BPW (phosphates) or D/E buffer (thiosulfate). Addition of neutralizers at 1X their respective concentrations in D/E buffer was required to allow Salmonella growth at the maximum CPC concentration (0.8%), while 2X neutralizer addition was required for Salmonella growth at the maximum PAA level (0.2%). Sanitizer neutralizers can assist pathogen survival and detection during routine food product testing.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Foods Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Foods Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Suiza