Indication, Technique and Long-term Results after Shoulder Arthrodesis Performed with Plate Fixation.
Z Orthop Unfall
; 156(1): 53-61, 2018 02.
Article
en En
| MEDLINE
| ID: mdl-29471558
AIM: Arthrodesis of the shoulder joint is a radical event, so it is difficult to explain its significance to patients. It has been the last resort in hopeless cases. Knowledge of long-term results and evaluation of advantages and disadvantages seems to be helpful in this regard. METHODS: Eleven patients with mean age of 45 (31â-â58) years were operated between 2000 and 2013. All patients could be included in the investigation (FU mean 8.5 [3â-â16] years; 8 male and 3 female; right 9, left 2). Patients had the following indications: persistent instability 5 (2 with epilepsy), rotator cuff rupture 2 (1× after combined latissimus dorsi and teres major transfer), brachial plexus injury/defect 2, locked dislocation 1 and posttraumatic arthropathy 1. Fixation with DC plate (pre-bent to 110°) was used in all cases; with special focus on placing at least one screw in the scapular neck. The targeted arthrodesis position was abduction 30°, forward flexion 30°, and internal rotation 30°. RESULTS: Active abduction improved from 12 to 63°, forward flexion from 21 to 79° and internal rotation from 10 to 47° (mean values). In the resting position with hanging arm aside, mean abduction was 3° and forward flexion 8°. Nine of 11 patients had considerable relief of pain, from 8.3 to 2.4 points VAS. Five patients rated the outcome as excellent, 3 as good and 1 as satisfactory. Nine patients would repeat the procedure. In summary, an Oxford Shoulder Score of 31.6 points was achieved, and SSV of 58%. Bony fusion was achieved in all cases, 3â-â4 months p.âo. in mean. There were no important neurological or angiological complications. CONCLUSIONS: Plate arthrodesis in the technique used achieves high fusion and a low complication rate. Relief of pain and functional improvement are astonishing. Analysis of our results indicates that correction of the positions mentioned above is necessary: i.âo. arthrodesis position for abduction 25° (by means of pre-bending plate of 105°), forward flexion 20° and internal rotation 30° are suggested.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Artrodesis
/
Luxación del Hombro
/
Articulación del Hombro
/
Placas Óseas
/
Neuropatías del Plexo Braquial
/
Lesiones del Manguito de los Rotadores
/
Lesiones del Hombro
/
Inestabilidad de la Articulación
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
Límite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Z Orthop Unfall
Asunto de la revista:
ORTOPEDIA
/
TRAUMATOLOGIA
Año:
2018
Tipo del documento:
Article
Pais de publicación:
Alemania