Your browser doesn't support javascript.
loading
The percutaneous absorption of soman in a damaged skin porcine model and the evaluation of WoundStat™ as a topical decontaminant.
Dalton, Christopher; Hall, Charlotte; Lydon, Helen; Jenner, John; Chipman, J Kevin; Graham, John S; Chilcott, Robert P.
Afiliación
  • Dalton C; a CBR Division , Dstl Porton Down , Salisbury , UK.
  • Hall C; b School of Biosciences , University of Birmingham , Birmingham , UK.
  • Lydon H; b School of Biosciences , University of Birmingham , Birmingham , UK.
  • Jenner J; c CBRN & Chemical Toxicological Research Group, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency , Chilton , UK.
  • Chipman JK; b School of Biosciences , University of Birmingham , Birmingham , UK.
  • Graham JS; c CBRN & Chemical Toxicological Research Group, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency , Chilton , UK.
  • Chilcott RP; a CBR Division , Dstl Porton Down , Salisbury , UK.
Cutan Ocul Toxicol ; 37(2): 172-179, 2018 Jun.
Article en En | MEDLINE | ID: mdl-28853336
PURPOSE: The aim of this study was to evaluate a candidate haemostat (WoundStat™), down-selected from previous in vitro studies, for efficacy as a potential skin decontaminant against the chemical warfare agent pinacoyl methylfluorophosphonate (Soman, GD) using an in vivo pig model. MATERIALS AND METHODS: An area of approximately 3 cm2 was dermatomed from the dorsal ear skin to a nominal depth of 100 µm. A discrete droplet of 14C-GD (300 µg kg-1) was applied directly onto the surface of the damaged skin at the centre of the dosing site. Animals assigned to the treatment group were given a 2 g application of WoundStat™ 30 s after GD challenge. The decontamination efficacy of WoundStat™ against GD was measured by the direct quantification of the distribution of 14C-GD, as well as routine determination of whole blood cholinesterase and physiological measurements. RESULTS: WoundStat™ sequestered approximately 70% of the applied 14C-GD. Internal radiolabel recovery from treated animals was approximately 1% of the initially applied dose. Whole blood cholinesterase levels decreased to less than 10% of the original value by 15 min post WoundStat™ treatment and gradually decreased until the onset of apnoea or until euthanasia. All treated animals showed signs of GD intoxication that could be grouped into early (mastication, fasciculations and tremor), intermediate (miosis, salivation and nasal secretions) and late onset (lacrimation, body spasm and apnoea) effects. Two of the six WoundStat™ treated animals survived the study duration. CONCLUSIONS: The current study has shown that the use of WoundStat™ as a decontaminant on damaged pig ear skin was unable to fully protect against GD toxicity. Importantly, the findings indicate that the use of WoundStat™ in GD contaminated wounds would not exacerbate GD toxicity. These data suggest that absorbent haemostatic products may offer some limited functionality as wound decontaminants.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Absorción Cutánea / Soman / Sustancias para la Guerra Química / Descontaminación / Inhibidores de la Colinesterasa Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Cutan Ocul Toxicol Asunto de la revista: DERMATOLOGIA / OFTALMOLOGIA / TOXICOLOGIA Año: 2018 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Absorción Cutánea / Soman / Sustancias para la Guerra Química / Descontaminación / Inhibidores de la Colinesterasa Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Cutan Ocul Toxicol Asunto de la revista: DERMATOLOGIA / OFTALMOLOGIA / TOXICOLOGIA Año: 2018 Tipo del documento: Article Pais de publicación: Reino Unido