Your browser doesn't support javascript.
loading
Sol-gel coated ion sources for liquid chromatography-direct electron ionization mass spectrometry.
Riboni, Nicolò; Magrini, Laura; Bianchi, Federica; Careri, Maria; Cappiello, Achille.
Afiliación
  • Riboni N; Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy.
  • Magrini L; Dipartimento di Scienze Pure e Applicate, Università degli Studi di Urbino "Carlo Bo", Piazza Rinascimento 6, 61029 Urbino, Italy.
  • Bianchi F; Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy. Electronic address: federica.bianchi@unipr.it.
  • Careri M; Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy.
  • Cappiello A; Dipartimento di Scienze Pure e Applicate, Università degli Studi di Urbino "Carlo Bo", Piazza Rinascimento 6, 61029 Urbino, Italy. Electronic address: achille.cappiello@uniurb.it.
Anal Chim Acta ; 978: 35-41, 2017 Jul 25.
Article en En | MEDLINE | ID: mdl-28595724
Advances in interfacing liquid chromatography and electron ionization mass spectrometry are presented. New ion source coatings synthesized by sol-gel technology were developed and tested as vaporization surfaces in terms of peak intensity, peak width and peak delay for the liquid chromatography-direct electron ionization mass spectrometry (Direct-EI) determination of environmental pollutants like polycyclic aromatic hydrocarbons and steroids. Silica-, titania-, and zirconia-based coatings were sprayed inside the stainless steel ion source and characterized in terms of thermal stability, film thickness and morphology. Negligible weight losses until 350-400 °C were observed for all the materials, with coating thicknesses in the 6 (±1)-11 (±2) µm range for optimal ionization process. The best performances in terms of both peak intensity and peak width were obtained by using the silica-based coating: the detection of the investigated compounds was feasible at low ng µl-1 levels with a good precision (RSD < 9% for polycyclic aromatic hydrocarbons and <11% for hormones).
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Anal Chim Acta Año: 2017 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Anal Chim Acta Año: 2017 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Países Bajos