Your browser doesn't support javascript.
loading
RP-HPLC Separation of Isomeric Withanolides: Method Development, Validation and Application to In situ Rat Permeability Determination.
Yaseen Malik, Mohd; Taneja, Isha; Raju, Kanumuri Siva Rama; Rahaman Gayen, Jiaur; Singh, Sheelendra Pratap; Sangwand, Neelam S; Wahajuddin, Muhammad.
Afiliación
  • Yaseen Malik M; Pharmacokinetics and Metabolism Division, CSIR-Central Drug Research Institute, Lucknow 226031, India.
  • Taneja I; Pharmacokinetics and Metabolism Division, CSIR-Central Drug Research Institute, Lucknow 226031, India.
  • Raju KSR; Academy of Scientific & Innovative Research, New Delhi 110020, India.
  • Rahaman Gayen J; Pharmacokinetics and Metabolism Division, CSIR-Central Drug Research Institute, Lucknow 226031, India.
  • Singh SP; Academy of Scientific & Innovative Research, New Delhi 110020, India.
  • Sangwand NS; Pharmacokinetics and Metabolism Division, CSIR-Central Drug Research Institute, Lucknow 226031, India.
  • Wahajuddin M; Academy of Scientific & Innovative Research, New Delhi 110020, India.
J Chromatogr Sci ; 55(7): 729-735, 2017 Aug 01.
Article en En | MEDLINE | ID: mdl-28407087
Withanolides are the group of active chemical constituents of Withania somnifera (L.) Dunal. Withaferin A, withanolide A and withanone presents three of the biologically most active constituents of this herb. These steroidal lactones are isomers of each other and thus, pose significant difficulty in their separation. In present study, a simple, specific and reliable RP-HPLC method has been developed and validated for their separation and simultaneous quantification. Separation was carried out on Lichrocart Purospher STAR RP-18e column (250 × 4.5 mm, 5 µm) using mobile phase, methanol and 0.01 M ammonium acetate buffer (pH 5) in the ratio 60:40, v/v. The calibration curves were linear (r2 > 0.99) for all the three compounds across concentration range of 1.56-50 µg/mL. The lower limit of quantification for all the analytes was 1.56 µg/mL. The intra-day and inter-day accuracy was between 88.65% and 110.66% and coefficient of variation was between 0.55 and 10.12. The analytes were stable under different storage conditions. The developed method was successfully applied to analyze the samples for simultaneous determination of permeability of the three withanolides in rats using in situ single-pass intestinal perfusion model. Withanolide A and withanone were found to be high permeability compounds while withaferin A could not be detected.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía Líquida de Alta Presión / Witanólidos / Intestino Delgado Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: J Chromatogr Sci Año: 2017 Tipo del documento: Article País de afiliación: India Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía Líquida de Alta Presión / Witanólidos / Intestino Delgado Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: J Chromatogr Sci Año: 2017 Tipo del documento: Article País de afiliación: India Pais de publicación: Estados Unidos