Your browser doesn't support javascript.
loading
Prehospital randomised assessment of a mechanical compression device in out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised trial and economic evaluation.
Gates, Simon; Lall, Ranjit; Quinn, Tom; Deakin, Charles D; Cooke, Matthew W; Horton, Jessica; Lamb, Sarah E; Slowther, Anne-Marie; Woollard, Malcolm; Carson, Andy; Smyth, Mike; Wilson, Kate; Parcell, Garry; Rosser, Andrew; Whitfield, Richard; Williams, Amanda; Jones, Rebecca; Pocock, Helen; Brock, Nicola; Black, John Jm; Wright, John; Han, Kyee; Shaw, Gary; Blair, Laura; Marti, Joachim; Hulme, Claire; McCabe, Christopher; Nikolova, Silviya; Ferreira, Zenia; Perkins, Gavin D.
Afiliación
  • Gates S; Warwick Clinical Trials Unit, University of Warwick, Coventry, UK.
  • Lall R; Warwick Clinical Trials Unit, University of Warwick, Coventry, UK.
  • Quinn T; Surrey Peri-operative Anaesthesia Critical Care Collaborative Research Group, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK (current address: Faculty of Health, Social Care and Education, Kingston University London and St George's, University of London, London, UK).
  • Deakin CD; South Central Ambulance Service NHS Foundation Trust, Otterbourne, UK.
  • Cooke MW; Warwick Clinical Trials Unit, University of Warwick, Coventry, UK.
  • Horton J; Heart of England NHS Foundation Trust, Birmingham, UK.
  • Lamb SE; Warwick Clinical Trials Unit, University of Warwick, Coventry, UK.
  • Slowther AM; Warwick Clinical Trials Unit, University of Warwick, Coventry, UK.
  • Woollard M; Oxford Clinical Trials Research Unit, University of Oxford, Oxford, UK.
  • Carson A; Warwick Clinical Trials Unit, University of Warwick, Coventry, UK.
  • Smyth M; Surrey Peri-operative Anaesthesia Critical Care Collaborative Research Group, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK (current address: Faculty of Health, Social Care and Education, Kingston University London and St George's, University of London, London, UK).
  • Wilson K; West Midlands Ambulance Service NHS Foundation Trust, Brierley Hill, UK.
  • Parcell G; Warwick Clinical Trials Unit, University of Warwick, Coventry, UK.
  • Rosser A; West Midlands Ambulance Service NHS Foundation Trust, Brierley Hill, UK.
  • Whitfield R; West Midlands Ambulance Service NHS Foundation Trust, Brierley Hill, UK.
  • Williams A; West Midlands Ambulance Service NHS Foundation Trust, Brierley Hill, UK.
  • Jones R; West Midlands Ambulance Service NHS Foundation Trust, Brierley Hill, UK.
  • Pocock H; Welsh Ambulance Services NHS Trust, St Asaph, UK.
  • Brock N; Welsh Ambulance Services NHS Trust, St Asaph, UK.
  • Black JJ; Welsh Ambulance Services NHS Trust, St Asaph, UK.
  • Wright J; South Central Ambulance Service NHS Foundation Trust, Otterbourne, UK.
  • Han K; South Central Ambulance Service NHS Foundation Trust, Otterbourne, UK.
  • Shaw G; South Central Ambulance Service NHS Foundation Trust, Otterbourne, UK.
  • Blair L; North East Ambulance Service NHS Foundation Trust, Newcastle upon Tyne, UK.
  • Marti J; Royal Victoria Infirmary, Newcastle upon Tyne, UK.
  • Hulme C; North East Ambulance Service NHS Foundation Trust, Newcastle upon Tyne, UK.
  • McCabe C; North East Ambulance Service NHS Foundation Trust, Newcastle upon Tyne, UK.
  • Nikolova S; North East Ambulance Service NHS Foundation Trust, Newcastle upon Tyne, UK.
  • Ferreira Z; Academic Unit of Health Economics, Leeds Institute of Health Sciences, University of Leeds, Leeds, UK.
  • Perkins GD; Academic Unit of Health Economics, Leeds Institute of Health Sciences, University of Leeds, Leeds, UK.
Health Technol Assess ; 21(11): 1-176, 2017 03.
Article en En | MEDLINE | ID: mdl-28393757
BACKGROUND: Mechanical chest compression devices may help to maintain high-quality cardiopulmonary resuscitation (CPR), but little evidence exists for their effectiveness. We evaluated whether or not the introduction of Lund University Cardiopulmonary Assistance System-2 (LUCAS-2; Jolife AB, Lund, Sweden) mechanical CPR into front-line emergency response vehicles would improve survival from out-of-hospital cardiac arrest (OHCA). OBJECTIVE: Evaluation of the LUCAS-2 device as a routine ambulance service treatment for OHCA. DESIGN: Pragmatic, cluster randomised trial including adults with non-traumatic OHCA. Ambulance dispatch staff and those collecting the primary outcome were blind to treatment allocation. Blinding of the ambulance staff who delivered the interventions and reported initial response to treatment was not possible. We also conducted a health economic evaluation and a systematic review of all trials of out-of-hospital mechanical chest compression. SETTING: Four UK ambulance services (West Midlands, North East England, Wales and South Central), comprising 91 urban and semiurban ambulance stations. Clusters were ambulance service vehicles, which were randomly assigned (approximately 1 : 2) to the LUCAS-2 device or manual CPR. PARTICIPANTS: Patients were included if they were in cardiac arrest in the out-of-hospital environment. Exclusions were patients with cardiac arrest as a result of trauma, with known or clinically apparent pregnancy, or aged < 18 years. INTERVENTIONS: Patients received LUCAS-2 mechanical chest compression or manual chest compressions according to the first trial vehicle to arrive on scene. MAIN OUTCOME MEASURES: Survival at 30 days following cardiac arrest; survival without significant neurological impairment [Cerebral Performance Category (CPC) score of 1 or 2]. RESULTS: We enrolled 4471 eligible patients (1652 assigned to the LUCAS-2 device and 2819 assigned to control) between 15 April 2010 and 10 June 2013. A total of 985 (60%) patients in the LUCAS-2 group received mechanical chest compression and 11 (< 1%) patients in the control group received LUCAS-2. In the intention-to-treat analysis, 30-day survival was similar in the LUCAS-2 (104/1652, 6.3%) and manual CPR groups [193/2819, 6.8%; adjusted odds ratio (OR) 0.86, 95% confidence interval (CI) 0.64 to 1.15]. Survival with a CPC score of 1 or 2 may have been worse in the LUCAS-2 group (adjusted OR 0.72, 95% CI 0.52 to 0.99). No serious adverse events were noted. The systematic review found no evidence of a survival advantage if mechanical chest compression was used. The health economic analysis showed that LUCAS-2 was dominated by manual chest compression. LIMITATIONS: There was substantial non-compliance in the LUCAS-2 arm. For 272 out of 1652 patients (16.5%), mechanical chest compression was not used for reasons that would not occur in clinical practice. We addressed this issue by using complier average causal effect analyses. We attempted to measure CPR quality during the resuscitation attempts of trial participants, but were unable to do so. CONCLUSIONS: There was no evidence of improvement in 30-day survival with LUCAS-2 compared with manual compressions. Our systematic review of recent randomised trials did not suggest that survival or survival without significant disability may be improved by the use of mechanical chest compression. FUTURE WORK: The use of mechanical chest compression for in-hospital cardiac arrest, and in specific circumstances (e.g. transport), has not yet been evaluated. TRIAI REGISTRATION: Current Controlled Trials ISRCTN08233942. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 21, No. 11. See the NIHR Journals Library website for further project information.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reanimación Cardiopulmonar / Servicios Médicos de Urgencia / Paro Cardíaco Extrahospitalario Tipo de estudio: Clinical_trials / Guideline / Health_economic_evaluation / Health_technology_assessment Límite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Health Technol Assess Asunto de la revista: PESQUISA EM SERVICOS DE SAUDE / TECNOLOGIA MEDICA Año: 2017 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reanimación Cardiopulmonar / Servicios Médicos de Urgencia / Paro Cardíaco Extrahospitalario Tipo de estudio: Clinical_trials / Guideline / Health_economic_evaluation / Health_technology_assessment Límite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Health Technol Assess Asunto de la revista: PESQUISA EM SERVICOS DE SAUDE / TECNOLOGIA MEDICA Año: 2017 Tipo del documento: Article Pais de publicación: Reino Unido