Immediate and short-term performance of a novel sirolimus-coated balloon during complex percutaneous coronary interventions. The FAtebenefratelli SIrolimus COated-balloon (FASICO) registry.
Cortese, Bernardo; di Palma, Gaetano; Latini, Roberto A; Elwany, Mostafa; Orrego, Pedro Silva; Seregni, Romano G.
Afiliación
  • Cortese B; Unità Operativa di Cardiologia, ASST Fatebenefratelli-Sacco, P.O. Fatebenefratelli. Electronic address: bcortese@gmail.com.
  • di Palma G; Unità Operativa di Cardiologia, ASST Fatebenefratelli-Sacco, P.O. Fatebenefratelli.
  • Latini RA; Unità Operativa di Cardiologia, ASST Fatebenefratelli-Sacco, P.O. Fatebenefratelli.
  • Elwany M; Unità Operativa di Cardiologia, ASST Fatebenefratelli-Sacco, P.O. Fatebenefratelli.
  • Orrego PS; Unità Operativa di Cardiologia, ASST Fatebenefratelli-Sacco, P.O. Fatebenefratelli.
  • Seregni RG; Unità Operativa di Cardiologia, ASST Fatebenefratelli-Sacco, P.O. Fatebenefratelli.
Cardiovasc Revasc Med ; 18(7): 487-491, 2017.
Article en En | MEDLINE | ID: mdl-28365415
BACKGROUND AND PURPOSES: Drug-coated balloons (DCB) currently represent an alternative to drug-eluting stents (DES) for the treatment of in-stent restenosis and they are also variably used for small coronary vessel and bifurcation lesion management. All DCB variably elute paclitaxel as an anti-proliferative drug. The first sirolimus coated balloon (SCB) received the CE mark in 2016, but its clinical performance has not been shown yet. METHODS AND RESULTS: FASICO in an all-comer registry of the first consecutive patients with at least one lesion treated with SCB between March and July 2016 at the first European centre that used this device. All patients were prospectively enrolled in a dedicated database. Primary endpoint was procedural success; co-primary endpoint was the rate of major adverse cardiac events at short-term follow-up. The 32 patients (34 lesions) enrolled had at least 6-month clinical follow up available. Forty-five percent had diabetes and indication to PCI was ISR in 47% of the cases. Lesions were always pre-dilated and device deployment was successful in all the cases. Procedural success was achieved in 100% of patients. We observed 3 cases of TLR at follow-up. CONCLUSIONS: SCB shows high immediate technical performance and adequate short-term efficacy and safety. The ongoing EASTBOURNE registry will shed light on mid-and long-term performance of this device in an adequately powered population.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fármacos Cardiovasculares / Angioplastia Coronaria con Balón / Enfermedad Coronaria / Sirolimus / Materiales Biocompatibles Revestidos / Catéteres Cardíacos Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Female / Humans / Male País/Región como asunto: Europa Idioma: En Revista: Cardiovasc Revasc Med Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2017 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fármacos Cardiovasculares / Angioplastia Coronaria con Balón / Enfermedad Coronaria / Sirolimus / Materiales Biocompatibles Revestidos / Catéteres Cardíacos Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Female / Humans / Male País/Región como asunto: Europa Idioma: En Revista: Cardiovasc Revasc Med Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2017 Tipo del documento: Article Pais de publicación: Estados Unidos