A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.
Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M.
Afiliación
  • Hellingman D; Department of Nuclear Medicine, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
  • Teixeira SC; Department of Nuclear Medicine, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
  • Donswijk ML; Department of Nuclear Medicine, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
  • Rijkhorst EJ; Department of Medical Physics and Technology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
  • Moliner L; Instituto de Instrumentación para Imagen Molecular (I3M), Universidad Politécnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain.
  • Alamo J; General Equipment for Medical Imaging S.A., C/Jerónimo de Monsoriu, 92, Bajo izq., 46022 Valencia, Spain.
  • Loo CE; Department of Radiology, The Netherlands Cancer Institute Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
  • Valdés Olmos RA; Department of Nuclear Medicine, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands; Interventional Molecular Imaging Laboratory and Nuclear Medicine Section, Department of Radiology, Leiden University Medical Centre, Albinusdreef 2
  • Stokkel MPM; Department of Nuclear Medicine, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
Rev Esp Med Nucl Imagen Mol ; 36(3): 158-165, 2017.
Article en En, Es | MEDLINE | ID: mdl-28038997
PURPOSE: To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18F-FDG uptake. MATERIALS AND METHODS: In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18F-FDG uptake areas within the tumour. RESULTS: Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. CONCLUSIONS: Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mama / Neoplasias de la Mama / Radiofármacos / Fluorodesoxiglucosa F18 Límite: Female / Humans Idioma: En / Es Revista: Rev Esp Med Nucl Imagen Mol Año: 2017 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mama / Neoplasias de la Mama / Radiofármacos / Fluorodesoxiglucosa F18 Límite: Female / Humans Idioma: En / Es Revista: Rev Esp Med Nucl Imagen Mol Año: 2017 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: España