Your browser doesn't support javascript.
loading
Investigation of the effect of mobile phase composition on selectivity using a solvent-triangle based approach in achiral SFC.
Muscat Galea, Charlene; Mangelings, Debby; Vander Heyden, Yvan.
Afiliación
  • Muscat Galea C; Vrije Universiteit Brussel (VUB), Center for Pharmaceutical Research (CePhaR), Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Laarbeeklaan 103, B-1090 Brussels, Belgium. Electronic address: charlene.galea@vub.ac.be.
  • Mangelings D; Vrije Universiteit Brussel (VUB), Center for Pharmaceutical Research (CePhaR), Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Laarbeeklaan 103, B-1090 Brussels, Belgium. Electronic address: debby.mangelings@vub.ac.be.
  • Vander Heyden Y; Vrije Universiteit Brussel (VUB), Center for Pharmaceutical Research (CePhaR), Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Laarbeeklaan 103, B-1090 Brussels, Belgium. Electronic address: yvanvdh@vub.ac.be.
J Pharm Biomed Anal ; 132: 247-257, 2017 Jan 05.
Article en En | MEDLINE | ID: mdl-27776301
Defining a method development methodology for achiral drug impurity profiling in SFC requires a number of steps. Initially, diverse stationary phases are characterized and a small number of orthogonal or dissimilar phases are selected for further method development. In this paper, we focus on a next step which is the investigation of the modifier composition on chromatographic selectivity. A solvent-triangle based approach is used in which blends of organic solvents, mainly ethanol (EtOH), propanol (PrOH), acetonitrile (ACN) and tetrahydrofuran (THF) mixed with methanol (MeOH) are tested as modifiers on six dissimilar stationary phases. The tested modifier blends were composed to have equal eluotropic strengths as calculated on bare silica. The modifier leads to minor changes in terms of elution order, retention and mixture resolution. However, varying only the modifier composition on a given stationary phase does not lead to the creation of dissimilar systems. Therefore the modifier composition is an optimization parameter, with the stationary phase being the factor determining most the selectivity of a given mixture in achiral SFC.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía con Fluido Supercrítico Idioma: En Revista: J Pharm Biomed Anal Año: 2017 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía con Fluido Supercrítico Idioma: En Revista: J Pharm Biomed Anal Año: 2017 Tipo del documento: Article Pais de publicación: Reino Unido