Your browser doesn't support javascript.
loading
Comparison of Magnetic Microbubbles and Dual-modified Microbubbles Targeted to P-selectin for Imaging of Acute Endothelial Inflammation in the Abdominal Aorta.
Wu, Weilan; Feng, Xuguang; Yuan, Ye; Liu, Ying; Li, Meiyu; Bin, Jianguo; Xiao, Yunbin; Liao, Wangjun; Liao, Yulin; Zhang, Wenzhu; Bin, Jianping.
Afiliación
  • Wu W; Department of Cardiology, Panyu Central Hospital, Guangzhou, China.
  • Feng X; StateKey Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
  • Yuan Y; StateKey Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
  • Liu Y; StateKey Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
  • Li M; StateKey Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
  • Bin J; Department of Cardiology, Guangzhou Eight People's Hospital, Guangzhou, China.
  • Xiao Y; StateKey Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
  • Liao W; Department of Cardiology, Guangzhou Eight People's Hospital, Guangzhou, China.
  • Liao Y; StateKey Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
  • Zhang W; StateKey Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
  • Bin J; Department of Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Mol Imaging Biol ; 19(2): 183-193, 2017 04.
Article en En | MEDLINE | ID: mdl-27672005
PURPOSE: Ultrasound molecular imaging (UMI) has potential to evaluate an inflammatory profile of endothelium. However, it is less successful in large arteries. This study compared magnetic microbubbles (MBs) selectively targeted to endothelial P-selectin and dual-targeting MBs in vitro and in vivo. PROCEDURES: MBs were modified with P-selectin antibody (MBPM) or isotype control antibody (MBCM) via a magnetic streptavidin bridge, and MBs were conjugated to P-selectin antibody (MBP) or both P-selectin antibody and PAA-sialyl Lewisx (MBD) via regular streptavidin linker. Adherence of MBs was determined by using a parallel plate flow chamber at variable shear stress (0.5-24 dyn/cm2). Adhesive and magnetic behaviors of MBs were analyzed at 4.0 dyn/cm2 or at a flow rate of 50 mm/s. Attachment of MBs to P-selectin was determined with contrast-enhanced ultrasound (CEU) imaging of murine abdominal aorta inflammation. The expression of P-selectin was assessed by immunohistochemistry. RESULTS: The adhesive efficacy of MBD was greater than MBP and MBCM, but lower than MBPM under all shear stress conditions (P < 0.05). The behaviors of fast-binding and rolling slow down were noted in MBD and MBPM; meanwhile, magnetic shifting of MBs centerline was presented in MBPM. Contrast video intensity (VI) from adhered MBPM to P-selectin of the inflammatory aorta was significantly higher than those from MBD and MBP (P < 0.05). CONCLUSIONS: MBPM may be a better molecular probe than MBD for detection of P-selectin on aorta with CEU, likely due to the shifting of axial distribution. Thus, it may improve the detection of the inflammatory profile on large arteries by UMI.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta Abdominal / Selectina-P / Células Endoteliales / Microburbujas / Imagen Molecular / Inflamación / Magnetismo Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta Abdominal / Selectina-P / Células Endoteliales / Microburbujas / Imagen Molecular / Inflamación / Magnetismo Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos