Your browser doesn't support javascript.
loading
Technical feasibility and safety of an intraoperative head-up display device during spine instrumentation.
Yoon, Jang W; Chen, Robert E; Han, Phillip K; Si, Phong; Freeman, William D; Pirris, Stephen M.
Afiliación
  • Yoon JW; Department of Neurosurgery, Mayo Clinic, 4500 San Pablo Road South, Jacksonville, FL, 32224, USA.
  • Chen RE; Emory University School of Medicine, 648 Pierce Dr NE, Atlanta, GA, 30307, USA.
  • Han PK; Georgia Institute of Technology, North Ave NW, Atlanta, GA, 30332, USA.
  • Si P; Georgia Institute of Technology, North Ave NW, Atlanta, GA, 30332, USA.
  • Freeman WD; Georgia Institute of Technology, North Ave NW, Atlanta, GA, 30332, USA.
  • Pirris SM; Departments of Neurosurgery, Neurology, and Critical Care, Mayo Clinic, 4500 San Pablo Road South, Jacksonville, FL, USA.
Int J Med Robot ; 13(3)2017 Sep.
Article en En | MEDLINE | ID: mdl-27569781
BACKGROUND: The primary aim of this study was to determine the safety and feasibility of capturing and streaming neuronavigation images onto a head-up display during spine instrumentation. METHODS: Using a novel device, neuronavigation images were captured and transferred wirelessly via a password-encrypted network to the head-up display. At the end of the procedure, the surgeons completed a survey to gather their opinions of the system. RESULTS: Forty pedicle screws were placed using the head-up display. The average screw placement time was slightly shorter when the head-up display was used (4.13 min with vs. 4.86 min without). The post-procedure survey demonstrated that 79% of surgeon's responses were positive. CONCLUSION: A wearable head-up display can benefit current neuronavigation systems, but larger, outcomes-based trials are needed. Higher processing speed would allow streaming of higher resolution images. Along with an enlarged display, these may significantly improve utilization of this technology. Copyright © 2016 John Wiley & Sons, Ltd.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Columna Vertebral / Monitoreo Intraoperatorio / Neuronavegación / Dispositivos Electrónicos Vestibles Tipo de estudio: Evaluation_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Med Robot Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Columna Vertebral / Monitoreo Intraoperatorio / Neuronavegación / Dispositivos Electrónicos Vestibles Tipo de estudio: Evaluation_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Med Robot Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido