Your browser doesn't support javascript.
loading
Comparison of various bone cement ossiculoplasty techniques and functional results.
Gungor, Volkan; Atay, Gamze; Bajin, M Demir; Yarali, Mehmet; Sarac, Sarp; Sennaroglu, Levent.
Afiliación
  • Gungor V; a Department of Otorhinolaryngology Head and Neck Surgery , Ankara Numune Education and Research Hospital , Ankara , Turkey ;
  • Atay G; b Department of Otorhinolaryngology Head and Neck Surgery , Hacettepe University Faculty of Medicine , Ankara , Turkey ;
  • Bajin MD; b Department of Otorhinolaryngology Head and Neck Surgery , Hacettepe University Faculty of Medicine , Ankara , Turkey ;
  • Yarali M; c Department of Audiology , Hacettepe University Faculty of Medicine , Ankara , Turkey ;
  • Sarac S; d Department of Otorhinolaryngology Head and Neck Surgery , Koc University Faculty of Medicine , Istanbul , Turkey.
  • Sennaroglu L; b Department of Otorhinolaryngology Head and Neck Surgery , Hacettepe University Faculty of Medicine , Ankara , Turkey ;
Acta Otolaryngol ; 136(9): 883-7, 2016 Sep.
Article en En | MEDLINE | ID: mdl-27118255
OBJECTIVE: In this study, functional results of different bone cement ossiculoplasty techniques are compared. METHODS: Retrospective case review at a tertiary referral center. Patients who underwent middle ear surgery and bone cement ossiculoplasty between 2006-2012 were included. A total of 52 patients, including 30 patients with 'Incus to stapes' (Group 1) and 13 patients with 'malleus to stapes' (Group 2), five patients with 'incudoplasty + stapedotomy' (Group 3), and four patients with 'malleus to incus' (Group 4) ossiculoplasty were enrolled in the study. Pre-operative and post-operative audiological findings of each group were evaluated. RESULTS: The mean hearing gain (the difference between pre-operative and post-operative air bone gap (ABG)) was 13 dB for Group 1, 30 dB for Group 2, 24 dB for Group 3, and 9 dB for Group 4. The pre-operative air pure tone averages (PTA) of groups 1, 2, and 3 improved significantly in the post-operative period (p < 0.05). Closure of post-operative ABG of patients to less than 20 dB and 10 dB were as follows: ∼70% and 43% in group 1; 86% and 76% in group 2; 100% and 60% in group 3; and 75% and 50% in group 4, respectively. CONCLUSIONS: The results showed that glass ionomer cement is a simple and effective method for reconstruction of ossicular discontinuity in various ossicular chain pathologies and can be an alternative to conventional rebridging techniques such as sculpted incus interposition or partial ossicular replacement prosthesis (PORP).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procedimientos Quirúrgicos Otológicos / Cementos para Huesos / Osículos del Oído / Cementos de Ionómero Vítreo / Pérdida Auditiva Conductiva Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Acta Otolaryngol Año: 2016 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procedimientos Quirúrgicos Otológicos / Cementos para Huesos / Osículos del Oído / Cementos de Ionómero Vítreo / Pérdida Auditiva Conductiva Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Acta Otolaryngol Año: 2016 Tipo del documento: Article Pais de publicación: Reino Unido