Implementation and Performance of Automated Software for Computing Right-to-Left Ventricular Diameter Ratio From Computed Tomography Pulmonary Angiography Images.
Kumamaru, Kanako K; George, Elizabeth; Aghayev, Ayaz; Saboo, Sachin S; Khandelwal, Ashish; Rodríguez-López, Sara; Cai, Tianrun; Jiménez-Carretero, Daniel; Estépar, Raúl San José; Ledesma-Carbayo, Maria J; González, Germán; Rybicki, Frank J.
Afiliación
  • Kumamaru KK; From the *Applied Imaging Science Laboratory, Department of Radiology, Brigham and Women's Hospital, Boston, MA; †Department of Radiology, Juntendo University, Tokyo, Japan; ‡Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX; §Biomedical Image Technologies, Universidad Politécnica de Madrid & CIBER-BBN, Madrid, Spain; ∥Surgical Planning Laboratory, Brigham and Women's Hospital, Boston; and ¶Madrid-MIT M+Visión Consortium, Research Laboratory of Electronics,
J Comput Assist Tomogr ; 40(3): 387-92, 2016.
Article en En | MEDLINE | ID: mdl-26938697
OBJECTIVE: The aim of this study was to prospectively test the performance and potential for clinical integration of software that automatically calculates the right-to-left ventricular (RV/LV) diameter ratio from computed tomography pulmonary angiography images. METHODS: Using 115 computed tomography pulmonary angiography images that were positive for acute pulmonary embolism, we prospectively evaluated RV/LV ratio measurements that were obtained as follows: (1) completely manual measurement (reference standard), (2) completely automated measurement using the software, and (3 and 4) using a customized software interface that allowed 2 independent radiologists to manually adjust the automatically positioned calipers. RESULTS: Automated measurements underestimated (P < 0.001) the reference standard (1.09 [0.25] vs1.03 [0.35]). With manual correction of the automatically positioned calipers, the mean ratio became closer to the reference standard (1.06 [0.29] by read 1 and 1.07 [0.30] by read 2), and the correlation improved (r = 0.675 to 0.872 and 0.887). The mean time required for manual adjustment (37 [20] seconds) was significantly less than the time required to perform measurements entirely manually (100 [23] seconds). CONCLUSIONS: Automated CT RV/LV diameter ratio software shows promise for integration into the clinical workflow for patients with acute pulmonary embolism.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Pulmonar / Embolia Pulmonar / Programas Informáticos / Reconocimiento de Normas Patrones Automatizadas / Angiografía por Tomografía Computarizada / Ventrículos Cardíacos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Guideline Límite: Humans / Middle aged Idioma: En Revista: J Comput Assist Tomogr Año: 2016 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Pulmonar / Embolia Pulmonar / Programas Informáticos / Reconocimiento de Normas Patrones Automatizadas / Angiografía por Tomografía Computarizada / Ventrículos Cardíacos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Guideline Límite: Humans / Middle aged Idioma: En Revista: J Comput Assist Tomogr Año: 2016 Tipo del documento: Article Pais de publicación: Estados Unidos