Status of the SPIRAL2 injector commissioning.
Thuillier, T; Angot, J; Barué, C; Bertrand, P; Biarrotte, J L; Canet, C; Denis, J-F; Ferdinand, R; Flambard, J-L; Jacob, J; Jardin, P; Lamy, T; Lemagnen, F; Maunoury, L; Osmond, B; Peaucelle, C; Roger, A; Sole, P; Touzery, R; Tuske, O; Uriot, D.
Afiliación
  • Thuillier T; LPSC, Université Grenoble Alpes, CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex, France.
  • Angot J; LPSC, Université Grenoble Alpes, CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex, France.
  • Barué C; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Bertrand P; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Biarrotte JL; IPN Orsay, Université Paris Sud, CNRS/IN2P3, 15 rue Georges Clémenceau, 91406 Orsay Cedex, France.
  • Canet C; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Denis JF; Irfu, CEA Saclay, DSM/Irfu/SACM, 91191 Gif Sur Yvette, France.
  • Ferdinand R; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Flambard JL; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Jacob J; LPSC, Université Grenoble Alpes, CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex, France.
  • Jardin P; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Lamy T; LPSC, Université Grenoble Alpes, CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex, France.
  • Lemagnen F; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Maunoury L; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Osmond B; GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5, France.
  • Peaucelle C; IPNL, Université de Lyon, Université Claude Bernard Lyon 1, CNRS/IN2P3, UMR5822, F-69622 Lyon, France.
  • Roger A; Irfu, CEA Saclay, DSM/Irfu/SACM, 91191 Gif Sur Yvette, France.
  • Sole P; LPSC, Université Grenoble Alpes, CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex, France.
  • Touzery R; Irfu, CEA Saclay, DSM/Irfu/SACM, 91191 Gif Sur Yvette, France.
  • Tuske O; Irfu, CEA Saclay, DSM/Irfu/SACM, 91191 Gif Sur Yvette, France.
  • Uriot D; Irfu, CEA Saclay, DSM/Irfu/SACM, 91191 Gif Sur Yvette, France.
Rev Sci Instrum ; 87(2): 02A733, 2016 Feb.
Article en En | MEDLINE | ID: mdl-26931951
The SPIRAL2 injector, installed in its tunnel, is currently under commissioning at GANIL, Caen, France. The injector is composed of two low energy beam transport lines: one is dedicated to the light ion beam production, the other to the heavy ions. The first light ion beam, created by a 2.45 GHz electron cyclotron resonance ion source, has been successfully produced in December 2014. The first beam of the PHOENIX V2 18 GHz heavy ion source was analyzed on 10 July 2015. A status of the SPIRAL2 injector commissioning is given. An upgrade of the heavy ion source, named PHOENIX V3 aimed to replace the V2, is presented. The new version features a doubled plasma chamber volume and the high charge state beam intensity is expected to increase by a factor of 1.5 to 2 up to the mass ∼50. A status of its assembly is proposed.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2016 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Estados Unidos