Your browser doesn't support javascript.
loading
Amplatzer Plug to Occlude the Internal Iliac Artery During Endovascular Aortic Aneurysm Repair: A Large Multicenter Study.
Warein, E; Feugier, P; Chaufour, X; Molin, V; Malikov, S; Bartoli, M A; Coscas, R; Picquet, J; Peyrot, H; Favre, J-P; Steinmetz, E; Ben Ahmed, S; Rosset, E.
Afiliación
  • Warein E; CHU Clermont-Ferrand, Department of Vascular Surgery, Clermont-Ferrand, France.
  • Feugier P; Chirurgie Vasculaire, HCL, Hôpital Édouard-Herriot Lyon, France.
  • Chaufour X; Department of Vascular Surgery, University Hospital of Toulouse, France.
  • Molin V; Department of Vascular Surgery, Amiens University Hospital, Amiens, France.
  • Malikov S; Service de Chirurgie Vasculaire et Endoluminale, CHU de Nancy, France.
  • Bartoli MA; APHM, Hôpital de la Timone, Service de Chirurgie Vasculaire, Marseille, France.
  • Coscas R; Service de Chirurgie Vasculaire, Hôpital Universitaire Ambroise Paré, Assistance Publique-Hôpitaux de Paris (AP-HP), Boulogne-Billancourt, Paris, France.
  • Picquet J; Service de Chirurgie Vasculaire et Thoracique, CHU d'Angers, Angers, France.
  • Peyrot H; CHU Clermont-Ferrand, Department of Radiology, Clermont-Ferrand, France.
  • Favre JP; Cardiovascular Surgery Unit, University Hospital St-Etienne, St-Priest en Jarez, France.
  • Steinmetz E; Service de Chirurgie Cardio-Vasculaire, CHU Le Bocage, Dijon, France.
  • Ben Ahmed S; CHU Clermont-Ferrand, Department of Vascular Surgery, Clermont-Ferrand, France.
  • Rosset E; CHU Clermont-Ferrand, Department of Vascular Surgery, Clermont-Ferrand, France; Clermont Université, Université Clermont-1, Faculté de Médecine, Clermont-Ferrand, France. Electronic address: erosset@chu-clermontferrand.fr.
Eur J Vasc Endovasc Surg ; 51(5): 641-6, 2016 05.
Article en En | MEDLINE | ID: mdl-26879098
OBJECTIVE: During endovascular repair of abdominal aortic aneurysms (EVAR), in the absence of a distal iliac landing zone, the Amplatzer plug is increasingly being used to replace other internal iliac artery (IIA) embolization techniques. This study aimed at assessing the technical success, complication occurrence, and durability of the Amplatzer plug for IIA embolization. METHOD: From January 1, 2007 to December 31, 2013, all consecutive patients who underwent internal iliac embolization with an Amplatzer plug during EVAR were included in the study. There were 169 patients, (160 men, 9 women, mean 75 ± 9 years), treated by unilateral (158 cases, 93%) or bilateral (11 cases, 7%) embolization of the IIA, performed either separately prior to (65 cases, 38.5%) or during EVAR (104 cases, 61.5%). Follow up CT scan and/or US scan were performed 1 month after treatment and yearly thereafter. The inclusions were done retrospectively but the series was continuous and consecutive. Data were collected and analyzed using acquisition REDCap software. RESULTS: The technical success rate was 97.6%. Failures were device migration (n = 1), navigation failure (n = 2), and release outside the target zone (n = 1). On average, 1.43 plugs were required to achieve the embolization. The average amount of contrast agent for the embolization procedure was 111 ± 51 mL and the radiation dose was 127,777 ± 89,528 mGy/cm(2). The total fluoroscopy time was 854 ± 538 seconds. No re-canalization of the IIA trunk was observed during follow up. Complications were buttock claudication (n = 41, 24.3%), which resolved in 24 cases (58.5%, 24/41) at the first follow up, and intestinal ischemia requiring limited bowel resection in two cases. CONCLUSION: This multicenter study is the largest published to date. It demonstrates the efficacy and reliability of the Amplatzer plug to embolize the IIA during EVAR, with few side effects.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Arteria Ilíaca Tipo de estudio: Clinical_trials Límite: Aged / Female / Humans / Male Idioma: En Revista: Eur J Vasc Endovasc Surg Asunto de la revista: ANGIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Arteria Ilíaca Tipo de estudio: Clinical_trials Límite: Aged / Female / Humans / Male Idioma: En Revista: Eur J Vasc Endovasc Surg Asunto de la revista: ANGIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Reino Unido